4.4 Article

Detection time comparison of non-hydrolysed sulphated metabolites of metenolone, mesterolone and 17α-methyltestosterone analysed by four different mass spectrometric techniques

期刊

DRUG TESTING AND ANALYSIS
卷 15, 期 8, 页码 853-864

出版社

WILEY
DOI: 10.1002/dta.3481

关键词

anabolic steroids; doping; GC-MS; LC-MS; sulphates

向作者/读者索取更多资源

The detection of anabolic androgenic steroids (AAS) is frequent among rule-breaking athletes. The long-term metabolites, particularly non-hydrolysed sulphated metabolites, have gained attention for their extended detection time. Liquid and gas chromatography-mass spectrometry (LC- and GC-MS) have been used to investigate their potential. However, the most promising metabolite on one technique may not exhibit the same behavior on the other. Consequently, a comparison was carried out to identify the most likely long-term sulphated metabolites of metenolone, mesterolone, and 17-alpha-methyltestosterone on four mass spectrometric instruments.
The frequent detection of anabolic androgenic steroids (AAS) indicates their popularity among rule-breaking athletes. The so called long-term metabolites play a crucial role in their detection, and non-hydrolysed sulphated metabolites have gained renewed interest, as research has demonstrated their extended detection time compared to the more conventional markers (e.g., for metenolone and mesterolone). Their potential has been investigated using liquid and gas chromatography-mass spectrometry (LC- and GC-MS). However, due to their complementary nature, chances are that the most promising metabolite on one technique does not necessarily exhibit the same behaviour on the other and vice versa. Therefore, a comparison was carried out where as a trial model, metenolone, mesterolone and 17 alpha-methyltestosterone were selected and the most likely long-term sulphated metabolites identified on four mass spectrometric instruments. Additionally, using a modified sample preparation procedure, comparison between conventional and non-hydrolysed sulphated metabolites between different GC-MS instruments was also included. When focusing on each individual marker, no cases were observed where a single metabolite provided a superior detection time on all instruments. Furthermore, for each AAS, there were incidences where a metabolite provided the best detection time on one instrument but could only be detected for a shorter period or not at all on other instruments. This demonstrates that metabolite detection windows and hence their added-value as target substance are unique and dependent on the analytical technique and not only on their pharmacokinetic behaviour. Consequently, in each case, a metabolite versus instrument evaluation is needed to maximise the probabilities of detecting doping offences.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据