4.4 Article

Continuous Glucose Monitoring-Based Composite Metrics: A Review and Assessment of Performance in Recent-Onset and Long-Duration Type 1 Diabetes

相关参考文献

注意:仅列出部分参考文献,下载原文获取全部文献信息。
Article Endocrinology & Metabolism

Closed-Loop Insulin Delivery Versus Sensor-Augmented Pump Therapy in Older Adults With Type 1 Diabetes (ORACL): A Randomized, Crossover Trial

Sybil A. A. McAuley et al.

Summary: Closed-loop insulin delivery is an effective treatment option for older adults with long-duration type 1 diabetes, increasing their time within the target blood glucose range and reducing the occurrence of hypoglycemia.

DIABETES CARE (2022)

Review Endocrinology & Metabolism

Complications of Diabetes and Metrics of Glycemic Management Derived From Continuous Glucose Monitoring

Michael Yapanis et al.

Summary: This review summarizes the relationship between continuous glucose monitoring (CGM)-derived metrics of glycemic variability and diabetes-related complications. The results show that glycemic variability and low time in range (TIR) are associated with microvascular and macrovascular complications of diabetes. Higher TIR is associated with reduced risk of various complications, while standard deviation of blood glucose levels (SD) and mean amplitude of glycemic excursions (MAGE) are associated with peripheral neuropathy.

JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM (2022)

Article Medicine, Research & Experimental

Investigating the efficacy of baricitinib in new onset type 1 diabetes mellitus (BANDIT)-study protocol for a phase 2, randomized, placebo controlled trial

M. Waibel et al.

Summary: The goal of this study is to determine if the JAK1/JAK2 inhibitor baricitinib Impairs type 1 diabetes (T1D) autoimmunity and preserves beta cell function. The study will be a double-blind, placebo-controlled randomized trial involving individuals aged 10-30 years with recent-onset T1D. If the preservation of beta cell function is successful, it could improve glucose control and prevent diabetes complications, which may warrant further trials and use in at-risk populations to prevent T1D.

TRIALS (2022)

Article Endocrinology & Metabolism

A Glycemia Risk Index (GRI) of Hypoglycemia and Hyperglycemia for Continuous Glucose Monitoring Validated by Clinician Ratings

David C. Klonoff et al.

Summary: This study developed a composite index called GRI to assist clinicians in interpreting the quality of CGM data, based on metrics like blood glucose range, mean glucose, and coefficient of variation. The GRI consists of two main components related to hypoglycemia and hyperglycemia, which can be graphically displayed on a GRI Grid for tracking individual glycemic changes over time.

JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY (2022)

Article Endocrinology & Metabolism

Essential Continuous Glucose Monitoring Metrics: The Principal Dimensions of Glycemic Control in Diabetes

Eslam Montaser et al.

Summary: This study aimed to identify the principal dimensions of glycemic control and found that the glycemic-metric space has a true dimensionality of 2. Principal component analysis confirmed two essential metrics, treatment efficacy and treatment safety, which explained most of the variance.

DIABETES TECHNOLOGY & THERAPEUTICS (2022)

Article Endocrinology & Metabolism

Efficacy of a Hybrid Closed-Loop Solution in Patients With Excessive Time in Hypoglycaemia: A Post Hoc Analysis of Trials With DBLG1 System

Pierre-Yves Benhamou et al.

Summary: DBLG1 significantly reduces time in hypoglycemia and improves time in range and glycemia risk index in patients with excessive time in hypoglycemia. Glycemia risk index is more sensitive to improvements in glycemia achieved with closed-loop than time in range.

JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY (2022)

Article Endocrinology & Metabolism

Closed-Loop Insulin Delivery Versus Sensor-Augmented Pump Therapy in Older Adults With Type 1 Diabetes (ORACL): A Randomized, Crossover Trial

Sybil A. McAuley et al.

Summary: Closed-loop insulin delivery is an effective treatment option for older adults with long-duration type 1 diabetes, resulting in higher time in range and reduced time spent in hypoglycemia.

DIABETES CARE (2022)

Article Endocrinology & Metabolism

Real-World Use of a New Hybrid Closed Loop Improves Glycemic Control in Youth with Type 1 Diabetes

Laurel H. Messer et al.

Summary: A study on youth using Control-IQ technology for 6 months showed significant improvement in glycemic control, especially for those with higher baseline HbA1c. System use was high at 6 months, with only a small proportion discontinuing use, indicating potential for sustaining results long term.

DIABETES TECHNOLOGY & THERAPEUTICS (2021)

Review Endocrinology & Metabolism

Quality of Glycemic Control: Assessment Using Relationships Between Metrics for Safety and Efficacy

David Rodbard

Summary: This review suggests that only two metrics are sufficient for monitoring patients or comparing different forms of management interventions: one for efficacy evaluation and one for safety evaluation. By analyzing the relationships between safety and efficacy metrics, sensitivity can be improved and the need for arbitrary scoring systems can be avoided, offering the advantage of simplicity in both concept and practice.

DIABETES TECHNOLOGY & THERAPEUTICS (2021)

Article Endocrinology & Metabolism

Role of Composite Glycemic Indices: A Comparison of the Comprehensive Glucose Pentagon Across Diabetes Types and HbA1c Levels

Suresh Rama Chandran et al.

DIABETES TECHNOLOGY & THERAPEUTICS (2020)

Review Endocrinology & Metabolism

A Review of Continuous Glucose Monitoring-Based Composite Metrics for Glycemic Control

Michelle Nguyen et al.

DIABETES TECHNOLOGY & THERAPEUTICS (2020)

Article Endocrinology & Metabolism

Assessment of Glucose Control Metrics by Discriminant Ratio

Vanessa Moscardo et al.

DIABETES TECHNOLOGY & THERAPEUTICS (2020)

Review Endocrinology & Metabolism

Glycaemic variability in diabetes: clinical and therapeutic implications

Antonio Ceriello et al.

LANCET DIABETES & ENDOCRINOLOGY (2019)

Article Endocrinology & Metabolism

The Relationship of Hemoglobin A1C to Time-in-Range in Patients with Diabetes

Robert A. Vigersky et al.

DIABETES TECHNOLOGY & THERAPEUTICS (2019)

Article Computer Science, Artificial Intelligence

Temporal case-based reasoning for type 1 diabetes mellitus bolus insulin decision support

Daniel Brown et al.

ARTIFICIAL INTELLIGENCE IN MEDICINE (2018)

Article Endocrinology & Metabolism

Glycemic Variability Percentage: A Novel Method for Assessing Glycemic Variability from Continuous Glucose Monitor Data

Thomas A. Peyser et al.

DIABETES TECHNOLOGY & THERAPEUTICS (2018)

Article Endocrinology & Metabolism

International Consensus on Use of Continuous Glucose Monitoring

Thomas Danne et al.

DIABETES CARE (2017)

Article Endocrinology & Metabolism

Measures of Glycemic Variability in Type 1 Diabetes and the Effect of Real-Time Continuous Glucose Monitoring

Ahmed H. El-Laboudi et al.

DIABETES TECHNOLOGY & THERAPEUTICS (2016)

Article Endocrinology & Metabolism

Evaluation of the Mean Absolute Glucose Change as a Measure of Glycemic Variability Using Continuous Glucose Monitoring Data

Klaus-Dieter Kohnert et al.

DIABETES TECHNOLOGY & THERAPEUTICS (2013)

Article Critical Care Medicine

Glucose variability is associated with intensive care unit mortality

Jeroen Hermanides et al.

CRITICAL CARE MEDICINE (2010)

Article Endocrinology & Metabolism

Statistical Tools to Analyze Continuous Glucose Monitor Data

William Clarke et al.

DIABETES TECHNOLOGY & THERAPEUTICS (2009)

Article Endocrinology & Metabolism

Improved Quality of Glycemic Control and Reduced Glycemic Variability with Use of Continuous Glucose Monitoring

David Rodbard et al.

DIABETES TECHNOLOGY & THERAPEUTICS (2009)

Article Endocrinology & Metabolism

Interpretation of Continuous Glucose Monitoring Data: Glycemic Variability and Quality of Glycemic Control

David Rodbard

DIABETES TECHNOLOGY & THERAPEUTICS (2009)

Article Endocrinology & Metabolism

FRAX™ and the assessment of fracture probability in men and women from the UK

J. A. Kanis et al.

OSTEOPOROSIS INTERNATIONAL (2008)

Article Endocrinology & Metabolism

A method for assessing quality of control from glucose profiles

N. R. Hill et al.

DIABETIC MEDICINE (2007)

Article Endocrinology & Metabolism

Evaluation of a new measure of blood glucose variability in diabetes

Boris P. Kovatchev et al.

DIABETES CARE (2006)