4.7 Article

Electrospun nanofiber composite membranes for geothermal brine treatment with lithium enrichment via membrane distillation

期刊

CHEMOSPHERE
卷 318, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.chemosphere.2023.137902

关键词

Nanofiber composite membranes; Membrane distillation; Geothermal brine; Brine concentration; Lithium enrichment; Electrospinning

向作者/读者索取更多资源

In this study, a composite electrospun nanofiber membrane was fabricated and used to treat geothermal brine with lithium enrichment. Silica nanoparticles were incorporated onto the surface of nanofibers using an in-situ growth technique. The fabricated membranes showed excellent separation performance with high salt rejection and adequate flux.
In this study, a composite electrospun nanofiber membrane was fabricated and used to treat a geothermal brine source with lithium enrichment. An in-situ growth technique was applied to incorporate silica nanoparticles on the surface of nanofibers with (3-Aminopropyl) triethoxysilane as the nucleation site. The fabricated composite nanofiber membrane was heat pressed to enhance the integration of the membrane and its mechanical stability. The fabricated membranes were tested to evaluate their performance in feedwater containing different con-centrations of NaCl in the range of 0-100 g/L, and the wetting resistivity of the membranes was examined. Finally, the optimal membrane was applied to treat the simulated geothermal brine. The experimental results revealed that the in-situ growth of nanoparticles and coating of flourosilane agent dramatically improved the separation performance of the membrane with high salt rejection, and adequate flux was achieved. The heat -pressed membrane obtained >99% salt rejection and flux of 14-19 L/m2h at varying feedwater salinity (0-100 g/L), and the concentration of the Li during the 24 h test reached >1100 ppm from the initial 360 ppm. Evaluation of the energy efficiency of the membranes showed that the heat-pressed membrane obtained the optimum energy efficiency in the high concentration of salts. Additionally, the economic analysis indicated that MD could achieve a levelized cost of 2.9 USD/m3 of lithium brine concentration as the heat source is within the feed. Overall, this technology would represent a viable alternative to the solar pond to concentrate Li brine, enabling a compact, efficient, and continuous operating system.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据