4.7 Article

Safety and Efficacy of Everolimus-Versus Sirolimus-Eluting Stents 5-Year Results From SORT OUT IV

期刊

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jacc.2015.11.051

关键词

drug-eluting stent(s); outcome; percutaneous coronary intervention; very late definite stent thrombosis

资金

  1. Abbott Vascular
  2. Boston Scientific
  3. Cordis
  4. Johnson Johnson
  5. Terumo
  6. St. Jude Medical
  7. Biosensors
  8. Biotronik
  9. Biosensors International
  10. Medtronic
  11. Abbot Vascular
  12. Abbott
  13. Cordis Johnson Johnson

向作者/读者索取更多资源

BACKGROUND Long-term safety and efficacy for everolimus-eluting stents (EES) versus those of sirolimus-eluting stents (SES) are unknown. OBJECTIVES This study compared 5-year outcomes for EES with those for SES from the SORT OUT IV (Scandinavian Organization for Randomized Trials with Clinical Outcome) trial. METHODS Five-year follow-up was completed for 2,771 patients (99.9%). Primary endpoint was a composite of major adverse cardiac events (MACE), including cardiac death, myocardial infarction (MI), target vessel revascularization (TVR), and definite stent thrombosis. RESULTS At 5-years, MACE occurred in 14.0% and 17.4% in the EES and SES groups, respectively (hazard ratio [HR]: 0.80, 95% confidence interval [CI]: 0.66 to 0.97; p = 0.02). The MACE rate did not differ significantly within the first year (HR: 0.96, 95% CI: 0.71 to 1.19; p = 0.79), but from years 1 through 5, the MACE rate was lower with EES (HR: 0.71, 95% CI: 0.55 to 0.90; p = 0.006; p interaction = 0.12). Definite stent thrombosis was lower with EES (0.4%) than with SES (2.0%; HR: 0.18, 95% CI: 0.07 to 0.46), with a lower risk of very late definite stent thrombosis in the EES group (0.2% vs. 1.4%, respectively; HR: 0.16, 95% CI: 0.05 to 0.53). When censoring the patients at the time of stent thrombosis, we found no significant differences between the 2 stent groups for MACE rates (HR: 0.89, 95% CI: 0.73 to 1.08; p = 0.23), target lesion revascularization (HR: 0.90, 95% CI: 0.64 to 1.27; p = 0.55), and MI (HR: 0.93, 95% CI: 0.64 to 1.36; p = 0.72). CONCLUSIONS At 5-year follow-up, MACE rate was significantly lower with EES-than with SES-treated patients, due largely due to a lower risk of very late definite stent thrombosis. (C) 2016 by the American College of Cardiology Foundation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据