Why do ventilation strategies matter in controlling infectious airborne particles? A comprehensive numerical analysis in isolation ward

期刊

BUILDING AND ENVIRONMENT
卷 231, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.buildenv.2023.110048

关键词

Ventilation strategy; Healthcare-associated infection; Isolation ward; Turbulent airflow; Particle dispersion

向作者/读者索取更多资源

A proper ventilation strategy in an isolation ward can improve indoor air quality and reduce the risk of healthcare-associated infections (HAI) and airborne diseases. This study proposes and examines ventilation strategies to reduce particle settlement in patients. The combination of a ceiling-mounted air diffuser and air curtain jet proves effective in preventing particle settlement on patients and reducing particles in the vicinity of medical staff.
A proper ventilation strategy in an isolation ward could promote better indoor air quality for the occupants. This could also reduce the risk of immunocompromised patients contracting healthcare-associated infections (HAI) or airborne diseases such as COVID-19, tuberculosis, and measles among others. This study aims to propose and examine appropriate ventilation strategies in a single-patient isolation ward that can reduce particle settlement in patients. A simplified CFD model of the isolation ward was developed and well-validated against established data. An RNG k-epsilon model and discrete phase model (DPM) were used to simulate airflow and particle transportation. The study examined the airflow and particle dispersion under a baseline case and four proposed ventilation strategies. Results showed that the baseline case study, which used the ceiling-mounted air curtain was insufficient to prevent the particles from dispersing into the vicinity of the patient. Likewise, the dilution effect under the baseline case and case 4 (wall-mounted air supply diffuser) were relatively weak due to the low air change rate (ACH) of 4/hr and 9/hr respectively. The ventilation strategy in case 4 has a negligible effect on reducing the particles (14%) settling on the patient although the ACH in case 4 was 2-times the baseline case. The present finding ascertains that utilising the combination of ceiling-mounted air diffuser and air curtain jet (case 3) results in zero particle settlement on both patient's and the patient's bed. It also reduced 57% of particles in the vicinity of the medical staff's breathing zone compared to the baseline case.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据