Semi-circle magnetophoretic separation under rotated magnetic field for colorimetric biosensing of Salmonella

期刊

BIOSENSORS & BIOELECTRONICS
卷 229, 期 -, 页码 -

出版社

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2023.115230

关键词

Magnetophoretic separation; Colorimetric biosensing; Platinum modified magnetic nanobead; Rotated high gradient magnetic field; Bacterial detection

向作者/读者索取更多资源

A new microfluidic magnetophoretic biosensor was developed using platinum modified immunomagnetic nanobeads for continuous-flow isolation of magnetic bacteria from free nanobeads, combined with nanozyme signal amplification for colorimetric biosensing of Salmonella. The biosensor could detect Salmonella as low as 41 CFU/mL within 40 minutes.
Magnetic separation was often applied to isolate and concentrate foodborne bacteria using immunomagnetic nanobeads before downstream bacterial detection. However, nanobead-bacteria conjugates (magnetic bacteria) were coexisting with excessive unbound nanobeads, limiting these nanobeads on magnetic bacteria to further act as signal probes for bacterial detection. Here, a new microfluidic magnetophoretic biosensor was elaboratively developed using a rotated high gradient magnetic field and platinum modified immunomagnetic nanobeads for continuous-flow isolation of magnetic bacteria from free nanobeads, and combined with nanozyme signal amplification for colorimetric biosensing of Salmonella. First, the platinum modified immunomagnetic nanobeads were mixed with the bacterial sample to form the magnetic bacteria, and magnetically separated to eliminate non-magnetic background. Then, the mixture of free immunomagnetic nanobeads and magnetic bacteria was injected with sheath flow (PBS) at higher flowrate into the semi-circle magnetophoretic separation channel under rotated magnetic field, which was generated by two repulsive cylindric magnets and their in-between ring iron gear, leading to continuous-flow isolation of magnetic bacteria from free immunomagnetic nanobeads because they suffered from different magnetic forces and thus had different deviating positions at the outlet. Finally, the separated magnetic bacteria and unbound magnetic nanobeads were respectively collected and used to catalyze coreless substrate into blue product, which was further analyzed using the microplate reader to obtain bacterial amount. This biosensor could determinate Salmonella as low as 41 CFU/mL in 40 min.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据