Precision and reliability study of hospital infusion pumps: a systematic review

期刊

BIOMEDICAL ENGINEERING ONLINE
卷 22, 期 1, 页码 -

出版社

BMC
DOI: 10.1186/s12938-023-01088-w

关键词

Infusion pumps; Precision; Reliability; Medical equipment

向作者/读者索取更多资源

This study aims to identify the planning and techniques used in the maintenance and management of hospital infusion pumps by systematically reviewing studies on the reliability and accuracy of these pumps over the past 10 years. The results indicate that there is still substantial room for improvement in the study of accuracy and reliability of infusion pumps.
BackgroundInfusion Pumps (IP) are medical devices that were developed in the 1960s and generate fluid flow at pressures higher than that of normal blood pressure. Various hospital sectors make use of them, and they have become indispensable in therapies requiring continuity and precision in the administration of medication and/or food. As they are classified Class III (high risk) equipment, their maintenance is crucial for proper performance of the device, as well as patient and operator safety. The principal consideration of the pump is the volume infused, and the device demands great attention to detail when being calibrated. A lack of necessary care with this equipment can lead to uncertainty in volume and precision during the administration of substances. Because of this, it is essential to evaluate its reliability, to prevent possible failures at time of execution. This control aims at the quality of the intended infusion result, becoming an indication of quality.MethodsThis systematic review summarizes studies done over the last 10 years (2011 to December 2021) that address the reliability and accuracy of hospital infusion pumps, in order to identify planning of maintenance and/or other techniques used in management of the equipment. The Prisma method was applied and the databases utilized were Embase, MEDLINE/Pubmed, Web of Science, Scopus, IEEE Xplore, and Science Direct. In addition, similar reviews were studied in Prospero and the Cochrane Library. For data analysis, softwares such as Mendeley, Excel, RStudio, and VOSviewer were used, and Robvis helped in plotting risk of bias results for studies performed with Cochrane tools.ResultsThe six databases selected produced 824 studies. After applying eligibility criteria (inclusion and exclusion), removing duplicates, and applying filters 1 and 2, 15 studies were included in the present review. It was found that the most relevant sources came from the Institute of Electrical and Electronics Engineers (IEEE) and that the most relevant keywords revolved around the terms (device failure, infusion pumps, adverse effects, complications, etc.). These results made clear that there remains substantial room for improvement as it relates to the study of accuracy and reliability of infusion.ConclusionsWe verified that the reliability and precision analysis of hospital infusion pumps need to be performed in a more detailed and consistent way. New developments, considering the model and IP specification, are intended, clearly explaining the adopted methodology.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据