Investigation of impingement heat transfer in double-wall cooling structures with corrugated impingement plate at small Reynolds numbers

期刊

APPLIED THERMAL ENGINEERING
卷 225, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.applthermaleng.2023.120204

关键词

Impingement; effusion cooling; Corrugated impingement plate; TLC; Heat transfer

向作者/读者索取更多资源

This study investigated the effect of a corrugated wall jet on impingement heat transfer and flow loss in a narrow target chamber. Results show that corrugated jet plates yield better heat transfer performance at a relatively high Reynolds number and low impinging distance. The discharge coefficient for the corrugated jet plate was lower than that of the flat jet plate, with the minimum reached at a certain corrugation amplitude.
This study investigated an impingement/effusion cooling scheme with a corrugated jet plate applicable to a high -temperature exhaust cooling nozzle. The primary objective was to evaluate the effect of the corrugated wall jet on the impingement heat transfer and flow loss in a narrow target chamber under a low jet Reynolds number ranging from 450 to 2700. Sinusoidal curves with different wavelengths were employed to model the corrugated jet plate, where impingement holes were located at the trough of the plate. The location of the impingement holes creates a staggering pattern relative to the effusion holes. The corrugated jet plates with relative ripple amplitudes (A/d) considered were 0.2, 0.5 and 0.8, and the results were compared with those of a flat jet plate. Three relative average jet-to-plate spacings, Have/d, were selected for use: 1.6, 2.6, and 3.6. The heat transferred over a smooth target surface by multiple jets was measured using the transient liquid crystal (TLC) method. Results show that the amplitude of the corrugated plate was found to profoundly influence the heat transfer of the target surface. The use of corrugated jet plates yielded a better heat transfer performance at a relatively high Re and low impinging distance. The optimal heat transfer performance was achieved at A/d of 0.5, which was 28 % higher than the flat plate. The discharge coefficient for the corrugated jet plate was 2-9.4 % lower than that of the flat jet plate at all Have/d and Re values, and the minimum discharge coefficient was reached at A/d of 0.2. Furthermore, internal impingement heat transfer and flow resistance characteristics of the corrugated impingement/effusion were correlated according to the experimental data.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据