4.7 Article

Dynamic heat transfer characteristics of ice storage in smooth-tube and corrugated-tube heat exchangers

期刊

APPLIED THERMAL ENGINEERING
卷 223, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.applthermaleng.2023.120037

关键词

Ice storage; Smooth tube; Corrugated tube; Prediction model

向作者/读者索取更多资源

The performances of smooth-tube and corrugated-tube heat exchangers for ice storage are compared in this paper. Numerical analysis and experiments show that the corrugated-tube heat exchanger has a shorter ice storage duration (25% reduction) and melting duration (16% reduction) compared to the smooth-tube heat exchanger. Additionally, the temperature change rate in the corrugated tube is faster than that in the smooth tube during both ice storage and melting processes.
The ice storage system is one of the most promising techniques for flexibility enhancement of building cooling load. In this paper, the performances of smooth-tube and corrugated-tube heat exchangers for ice storage are compared by experiments and numerical simulation. The heat transfer process of the ice storage and melting within the heat exchangers is numerically analyzed used Python. The fast one-dimensional numerical model is verified by the experimental results. The temperature variation of the heat transfer fluid (HTF) in the corrugated tube is analyzed and compared with that in the smooth tube. The results show that under the same conditions, the ice storage duration of the corrugated tube is shortened by 25% and the melting duration is shortened by 16% compared with those of the smooth tube. During the ice storage process, the temperature difference between the inlet and outlet of the heat transfer fluid in the corrugated tube is 0.4 degrees C less than that of the smooth tube on average. The temperature change rate is 30% faster than that of the smooth tube. During the melting process, the temperature difference between the inlet and outlet of the heat transfer fluid in the corrugated tube is 0.1 degrees C higher than that of the smooth tube on average, and the temperature change rate of corrugated-tube heat exchanger is 2.5 times and 9 times faster than that of the smooth tube during the ice-storage and melting process. The corrugated-tube heat exchanger has superior performances in ice storage system in the comparison with the smooth-tube heat exchanger.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据