Spectra, fluence and absorbed doses in sensitive organs due to scattered X-rays during a chest CT

期刊

APPLIED RADIATION AND ISOTOPES
卷 194, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.apradiso.2023.110723

关键词

Dosimetry; Computed tomography; MCNP5; Scattered radiation; X-rays

向作者/读者索取更多资源

The use of ionizing radiation for medical purposes is increasing, especially in diagnostic imaging such as computed tomography (CT). However, this also leads to increased exposure to radiation for both patients and healthcare professionals. CT scans, although providing detailed and high-quality images, contribute to a significant portion of the medical radiation dose accumulated by the patient. This study aims to estimate the absorbed dose in sensitive organs due to scattered radiation during a chest CT.
The use of ionizing radiation for the treatment and diagnosis of diseases is becoming more frequent. The technologies associated with diagnostic imaging are constantly evolving, allowing faster and cheaper diagnoses to benefit the patient. However, this has caused an increase in the exposure to ionizing radiation of patients and health professionals. One of the diagnostic techniques for obtaining high-resolution anatomical images of patients is computed tomography (CT). Due to the detail and quality of the images obtained with CT, its use is becoming more frequent. The information provided by these images allows the specialist to make better diagnoses; however, exposure to X-rays deposits a dose in the patient. CT represents approximately 20% of all Xray examinations but it is responsible for 70% of the medical dose accumulated by the patient. During the acquisition of the images, the highest dose is deposited in the area of the body whose image is to be obtained. During the incidence of X-rays, there is dispersion of these that reach sensitive organs whose dose is not evaluated. The objective of this work was to estimate, using Monte Carlo methods, the fluence and X-ray spectra and to obtain a factor that allows knowing the absorbed dose in sensitive organs due to scattered radiation during a chest CT. With the MCNP5 code, the CT equipment and a hybrid anthropomorphic phantom, type BOMAB it was found that the absorbed dose in these organs depends on the size of the organ and the distance between the organ and the surface of the slice on the thorax where the X-rays are incident.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据