4.8 Article

Development of nanomodified-cementitious composite using phase change material for energy saving applications

期刊

APPLIED ENERGY
卷 340, 期 -, 页码 -

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.apenergy.2023.121067

关键词

Energy saving; Microencapsulation; Mortar; Multi -walled carbon nanotubes; Phase change material; Silica fume

向作者/读者索取更多资源

In this study, a nanoengineered thermal-energy storing cementitious composite was developed by incorporating micro-encapsulated phase change material (m-PCM) and a combination of multi-walled carbon nanotubes (MWCNTs) and silica fume (SF) for energy-saving purposes. The addition of m-PCM led to a decrease in mechanical strength, but the addition of SF/MWCNTs significantly enhanced the compressive strength of m-PCM mortars. The thermal-cycling test results showed that the energy requirement for thermal regulation in m-PCM mortars with MWCNTs was reduced by approximately 60% compared to the control specimen.
In this study, a nanoengineered thermal-energy storing cementitious composite incorporated with a micro -encapsulated phase change material (m-PCM) and the combination of multi-walled carbon nanotubes (MWCNTs) and silica fume (SF), were developed for energy-saving purposes. m-PCM with a phase-change temperature of 5.5 degrees C and an enthalpy of 84 J/g was added to create latent heat storage in cement mortar. MWCNTs were added to improve the mechanical and thermal performance of the cementitious composite. m-PCM was incorporated in the cement mortar in proportions of 5%, 10%, and 15% by binder weight. However, the dosage of MWCNTs and SF kept constant at 0.05% and 10% by binder weight, respectively. A uniaxial compression test was performed to analyze the effect of m-PCM on the mechanical properties of the mortar. The compression test results showed a significant decrease in mechanical strength owing to the addition of m-PCMs. However, the addition of SF/ MWCNTs significantly enhanced the compressive strength of m-PCM mortars. A thermal-cycling test, assisted by an electrically-controlled-heated wire system, was performed to study the thermal response of nanoengineered m-PCM mortars with respect to varying ambient temperatures. The results revealed that the energy requirement for thermal regulation in m-PCM mortars with MWCNTs was reduced by approximately 60% as compared to the control specimen.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据