4.8 Article

Controlled Growth of MoS2 on Dendritic Ferric Oxide to Enhance Electrochemiluminescence of Nitrogen-Doped Carbon Quantum Dots for Sensitive Immunoassay

期刊

ANALYTICAL CHEMISTRY
卷 95, 期 16, 页码 6655-6663

出版社

AMER CHEMICAL SOC
DOI: 10.1021/acs.analchem.3c00058

关键词

-

向作者/读者索取更多资源

This article introduces a novel electrochemiluminescence (ECL) biosensor for the detection of neuron-specific enolase (NSE), a biomarker for small cell lung cancer. The biosensor utilizes nitrogen-doped carbon quantum dots (N-CQDs) as emitters and molybdenum sulfide/ferric oxide (MoS2@Fe2O3) nanocomposites as a coreaction accelerator. The N-CQDs exhibit low excitation potential and maintain the activity of immune molecules, while the MoS2@Fe2O3 nanocomposites provide a large number of binding sites for immune molecules and accelerate the coreaction with hydrogen peroxide.
The essential expansion of electrochemiluminescence (ECL) technology into clinical detection relies on sensitive and stable signal and maintenance of the activity of the immune molecules during the analysis. This poses a critical challenge for an ECL biosensor as a luminophore in general requires high potential excitation resulting in a strong ECL signal; nevertheless, it has an irreversible effect on the activity of the antigen or antibody. Herein, a novel electrochemiluminescence (ECL) biosensor utilizing nitrogen-doped carbon quantum dots (N-CQDs) as emitters and molybdenum sulfide/ferric oxide (MoS2@Fe2O3) nanocomposites as a coreaction accelerator was developed for detection of neuron-specific enolase (NSE), a biomarker of small cell lung cancer. The doping of nitrogen allows the CQDs to exhibit ECL signals with low excitation potential, with a more viable activity possible for immune molecules. MoS2@Fe2O3 nanocomposites exhibit superior coreaction acceleration characteristics in hydrogen peroxide than any single component of them, and the highly branched dendrite microstructure provides a large number of binding sites for immune molecular, which is an inevitable factor for trace detection. In addition, ion beam sputtering gold particle technology is introduced into the sensor fabrication via an Au-N bond, which will provide sufficient density orientation for capturing the antibody load via the Au-N bonds. With excellent repeatability, stability, and specificity, the as-purposed sensing platform showed differentiated ECL responses of NSE range from 10.00 fg/mL to 500 ng/mL, and the limit of detection (LOD) was calculated of 6.30 fg/mL (S/N = 3). The proposed biosensor is prospective to provide a new avenue for the analysis of NSE or other biomarkers.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据