4.7 Article

A dual-signal fluorescent colorimetric tetracyclines sensor based on multicolor carbon dots as probes and smartphone-assisted visual assay

期刊

ANALYTICA CHIMICA ACTA
卷 1247, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.aca.2023.340843

关键词

Carbon dots; Ratiometric fluorescence sensor; Colorimetric; Tetracyclines; Visual quantitation

向作者/读者索取更多资源

A ratiometric fluorescence sensor using europium-doped carbon dots (Eu-CDs) as probes was developed for detecting tetracyclines under alkaline conditions. The sensor showed a wider linear detection range compared to reported europium ions-based tetracyclines sensors. A smartphone with RGB color picker was employed to analyze the concentration of tetracyclines, providing a new visual detection method. The accuracy of the sensor was comparable to the China national standard method, and it has promising applications in the real-time monitoring of tetracyclines in food and the environment.
The widespread presence of tetracyclines in the environment has raised concerns about the potential risks to ecosystems and human health. The ratiometric fluorescence sensor for detecting tetracyclines was developed using europium-doped carbon dots (Eu-CDs) as probes under alkaline conditions. The sensing mechanism of sensor for tetracyclines was considered as inner filter effect (IFE), antenna effect (AE), and self-quenching effect (SQE). The sensor had a wide linear detection range than the reported europium ions-based tetracyclines sensors. The linear detection ranges of oxytetracycline (OTC), tetracycline (TC), doxycycline (DC) and chlorotetracycline (CTC) were respectively 0.00-603.75 mu M, 0.00-623.82 mu M, 0.00-594.61 mu M and 0.00-601.54 mu M, and the corresponding detection limits were respectively 9.50 nM, 15.80 nM, 10.40 nM and 90.30 nM. The smartphone with RGB Color Picker was further employed to analyze the concentration of tetracyclines, which provided a new method for visual tetracyclines detection. The application of Eu-CDs test paper was also explored, and the results showed that the Eu-CDs test paper has great potential application in the visual detection of tetracyclines. In addition, the accuracy of the established tetracyclines sensor was compared with that of the China national standard method by high-performance liquid chromatography (HPLC), and the results showed that the estab-lished method in this work has similar accuracy to the China national standard method. The sensor has been employed to detect tetracyclines in the actual samples with satisfactory results, which indicated that this method has promising applications in the real-time monitoring tetracyclines of food and environment.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据