4.7 Article

Landscape-scale mapping of soil salinity with multi-height electromagnetic induction and quasi-3d inversion in Saharan Oasis, Tunisia

期刊

AGRICULTURAL WATER MANAGEMENT
卷 284, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.agwat.2023.108330

关键词

Electromagnetic induction; Tunisian Oasis; Multi-heightsECa measurements; Quasi-3d inversion; 3d soil salinity mapping

向作者/读者索取更多资源

Approximately half of Tunisia's irrigated area is affected by soil salinization due to arid and semi-arid conditions, low-quality water irrigation, shallow and saline groundwater, and poor drainage. This study used non-invasive electromagnetic induction (EMI) instrument, EM38, to collect apparent soil electrical conductivity (ECa) data and estimated the spatial distribution of true soil electrical conductivity (sigma) using a quasi-3d (q-3d) inversion algorithm. The results showed that the inversion of ECa measured at 0 and 0.2 m heights had the best coefficient of determination (R2 = 0.61) between sigma and ECe.
Approximately half of Tunisia's irrigated area suffers from soil salinization due to arid and semi-arid conditions, irrigation with low-quality water, shallow and saline groundwater, and poor drainage. To manage salt-affected soils, efficient assessment methods are needed to map soil salinity in irrigated lands and to evaluate the performance of crop, water, and soil management strategies. In this study, apparent soil electrical conductivity (ECa) data were collected using a non-invasive electromagnetic induction (EMI) instrument, EM38, at different dipole orientations and heights from the soil surface, across the large agricultural area of Fatnassa Saharan (an oasis in southern Tunisia). Using a quasi-3d (q-3d) inversion algorithm, the spatial distribution of true soil electrical conductivity (sigma) was estimated and the potential for prediction of the electrical conductivity of the saturated soil paste extract (ECe) from inverted ECa data was evaluated, by establishing a linear regression (LR) between sigma and ECe collected at 51 reference points. The results indicate that the q-3d inversion of ECa measured at 0 and 0.2 m heights gives the best coefficient of determination (R2) between sigma and ECe (R2 = 0.61). Calibration procedure was performed afterward to develop a single calibration equation and an independent validation dataset to evaluate the robustness of the obtained calibration model. The calibration-validation procedure shows moderate strength (R2 = 0.56), good accuracy with the root mean square error (RMSE) of 2.94 dS/m, small bias with mean error (ME) of - 0.56 dS/m, and an acceptable Lin's concordance correlation coefficient (LCCC) of 0.80. Our study reveals the applicability of using the proposed methodology, based on inversion of ECa data collected at multiple heights and orientations to develop a single regional calibration and to efficiently estimate ECe at any depth across the irrigation district. Also, in the absence of recent devolved multicoil EMI instruments, ECa data measured using a single coil instrument but at different heights can provide sufficient data, required for inversion modelling and quantitative investigation of soil properties. The prediction results reveal that the soil of the oasis is moderately to severely saline which may adversely affect agricultural productivity and the sustainability of crop production.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据