期刊
PHYSICS & IMAGING IN RADIATION ONCOLOGY
卷 25, 期 -, 页码 -出版社
ELSEVIER
DOI: 10.1016/j.phro.2022.12.003
关键词
Electroanatomical mapping; Radiotherapy planning; Cardiac radioablation; Quality assurance; CARDIO-RT
A novel quality assurance process for EAM-to-RTPI target transport was developed and evaluated within the multi-center multi-platform framework of the RAVENTA trial. The CARDIO-RT software enabled platform independent registration and automated segmentation of LV-RTC. Structural analyses revealed substantial differences between manual target transfer and target transport using CARDIO-RT in five clinical cases.
A novel quality assurance process for electroanatomical mapping (EAM)-to-radiotherapy planning imaging (RTPI) target transport was assessed within the multi-center multi-platform framework of the RAdiosurgery for VENtricular TAchycardia (RAVENTA) trial. A stand-alone software (CARDIO-RT) was developed to enable platform independent registration of EAM and RTPI of the left ventricle (LV), based on pre-generated radio-therapy contours (RTC). LV-RTC were automatically segmented into the American-Heart-Association 17 -segment-model and a manual 3D-3D method based on EAM 3D-geometry data and a semi-automated 2D-3D method based on EAM screenshot projections were developed. The quality of substrate transfer was evaluated in five clinical cases and the structural analyses showed substantial differences between manual target transfer and target transport using CARDIO-RT.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据