The in vivo location of edge- wear in hip arthroplasties

S. Bergiers et al.

Summary: Edge loading in metal on metal hip arthroplasties, resulting in increased wear rates and ultimately failure, was predominantly located along the superior acetabular edge. The position of the edge wear was influenced by the cup's angle of inclination and anteversion, suggesting a potential relationship with hip joint forces and walking gait patterns. Further research using this method could enhance the understanding of optimal and safe acetabular component positioning.

BONE & JOINT RESEARCH (2021)

Article Engineering, Mechanical

Quantifying material loss from the bearing surfaces of retrieved hip replacements: Method validation

Sean Bergiers et al.

TRIBOLOGY INTERNATIONAL (2020)

Article Computer Science, Interdisciplinary Applications

Accurate reconstructions of pelvic defects and discontinuities using statistical shape models

Alexander Meynen et al.

COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING (2020)

Article Cell & Tissue Engineering

Does diametrical clearance influence the wear of Pinnacle hip implants?

S. Bergiers et al.

BONE & JOINT RESEARCH (2020)

Editorial Material Orthopedics

Death of the Lewinnek Safe Zone

Lawrence D. Dorr et al.

JOURNAL OF ARTHROPLASTY (2019)

Article Orthopedics

Method for quantitative assessment of acetabular bone defects

Georg Hettich et al.

JOURNAL OF ORTHOPAEDIC RESEARCH (2019)

Article Cell & Tissue Engineering

Wear performance of retrieved metal-on-metal Pinnacle hip arthroplasties implanted before and after 2007

S. Bergiers et al.

BONE & JOINT RESEARCH (2018)

Article Computer Science, Interdisciplinary Applications

Virtual anatomical reconstruction of large acetabular bone defects using a statistical shape model

Peter Vanden Berghe et al.

COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING (2017)

Article Orthopedics

Is there a distinct pattern to the acetabular labrum and articular cartilage damage in the non-dysplastic hip with instability?

Kotaro R. Shibata et al.

KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY (2017)

Article Orthopedics

Is the Damage of Cartilage a Global or Localized Phenomenon in Hip Dysplasia, Measured by dGEMRIC?

Andreas Hingsammer et al.

CLINICAL ORTHOPAEDICS AND RELATED RESEARCH (2013)

Article Engineering, Mechanical

Predicting the wear of hard-on-hard hip joint prostheses

M. S. Uddin et al.

Article Engineering, Biomedical

Edge loading in metal-on-metal hips: low clearance is a new risk factor

Richard J. Underwood et al.

PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE (2012)

Review Orthopedics

Metal-on-metal bearings THE EVIDENCE SO FAR

F. S. Haddad et al.

JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME (2011)

Article Orthopedics

A comparison of explanted Articular Surface Replacement and Birmingham Hip Resurfacing components

R. Underwood et al.

JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME (2011)

Article Orthopedics

Adverse reaction to metal debris following hip resurfacing THE INFLUENCE OF COMPONENT TYPE, ORIENTATION AND VOLUMETRIC WEAR

D. J. Langton et al.

JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME (2011)

Review Orthopedics

Bioengineering reasons for the failure of metal-on-metal hip prostheses AN ENGINEER'S PERSPECTIVE

J. Fisher

JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME (2011)

Article Orthopedics

Failure Modes of 433 Metal-on-Metal Hip Implants: How, Why, and Wear

Edward Ebramzadeh et al.

ORTHOPEDIC CLINICS OF NORTH AMERICA (2011)

Article Neurosciences

Effect of hip angle on anterior hip joint force during gait

Cara L. Lewis et al.

GAIT & POSTURE (2010)

Article Biophysics

Contributions of individual muscles to hip joint contact force in normal walking

Tomas A. Correa et al.

JOURNAL OF BIOMECHANICS (2010)

Article Orthopedics

Analysis of wear of retrieved metal-on-metal hip resurfacing implants revised due to pseudotumours

Y. -M. Kwon et al.

JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME (2010)

Article Orthopedics

Hip damage occurs at the zone of femoroacetabular impingement

M. Tannast et al.

CLINICAL ORTHOPAEDICS AND RELATED RESEARCH (2008)

Article Orthopedics

Modes of implant failure after hip resurfacing:: Morphological and wear analysis of 267 retrieval specimens

Michael M. Morlock et al.

JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME (2008)

Article Orthopedics

The effect of component size and orientation on the concentrations of metal ions after resurfacing arthroplasty of the hip

D. J. Langton et al.

JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME (2008)

Article Computer Science, Artificial Intelligence

Instantiation and registration of statistical shape models of the femur and pelvis using 3D ultrasound imaging

Dean C. Barratt et al.

MEDICAL IMAGE ANALYSIS (2008)

Article Orthopedics

The John Charnley Award -: A study of inplant failure in metal-on-metal surface arthroplasties

Pat Campbell et al.

CLINICAL ORTHOPAEDICS AND RELATED RESEARCH (2006)

Article Biophysics

Hip contact forces and gait patterns from routine activities

G Bergmann et al.

JOURNAL OF BIOMECHANICS (2001)