4.3 Article

An Optimal Approach for Heart Sound Classification Using Grid Search in Hyperparameter Optimization of Machine Learning

期刊

BIOENGINEERING-BASEL
卷 10, 期 1, 页码 -

出版社

MDPI
DOI: 10.3390/bioengineering10010045

关键词

heart sound signal; MFCC; grid search; k-nearest neighbor; artificial neural networks; random forest; support vector machine

向作者/读者索取更多资源

Heart-sound auscultation is a widely used method for cardiovascular disorder detection, but it relies on the skill and judgment of physicians. This study proposes an optimal heart-sound classification method based on machine learning techniques for predicting cardiovascular diseases. The method achieved high accuracy performance of 95.78% and 76.31% on PhysioNet Challenge 2016 and 2022 datasets, respectively, demonstrating its potential as an additional tool for diagnosing heart sound abnormalities.
Heart-sound auscultation is one of the most widely used approaches for detecting cardiovascular disorders. Diagnosing abnormalities of heart sound using a stethoscope depends on the physician's skill and judgment. Several studies have shown promising results in automatically detecting cardiovascular disorders based on heart-sound signals. However, the accuracy performance needs to be enhanced as automated heart-sound classification aids in the early detection and prevention of the dangerous effects of cardiovascular problems. In this study, an optimal heart-sound classification method based on machine learning technologies for cardiovascular disease prediction is performed. It consists of three steps: pre-processing that sets the 5 s duration of the PhysioNet Challenge 2016 and 2022 datasets, feature extraction using Mel frequency cepstrum coefficients (MFCC), and classification using grid search for hyperparameter tuning of several classifier algorithms including k-nearest neighbor (K-NN), random forest (RF), artificial neural network (ANN), and support vector machine (SVM). The five-fold cross-validation was used to evaluate the performance of the proposed method. The best model obtained classification accuracy of 95.78% and 76.31%, which was assessed using PhysioNet Challenge 2016 and 2022, respectively. The findings demonstrate that the suggested approach obtained excellent classification results using PhysioNet Challenge 2016 and showed promising results using PhysioNet Challenge 2022. Therefore, the proposed method has been potentially developed as an additional tool to facilitate the medical practitioner in diagnosing the abnormality of the heart sound.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据