4.1 Article

Experimental data from gas burner fires in residential structure with HVAC system

期刊

DATA IN BRIEF
卷 46, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.dib.2022.108825

关键词

Fire model CFD; Validation gas burner; Residential structures ventilation; HVAC

向作者/读者索取更多资源

The fire modeling community lacks full-scale experimental data on fires in residential-style structures with HVAC systems, as well as data on the generation and transport of H2O due to combustion. Propane gas burner fire experiments were conducted in a purpose-built two-story structure to measure temperature, pressure, velocity, and gas concentrations. The experiments aimed to assess heat and gas species transfer under different conditions.
The fire modeling community currently lacks full-scale experimental data from fires in residential-style structures with heating, ventilation, and air conditioning (HVAC) systems. Further, there is an absence of data quantifying the generation of H2O due to combustion and the subsequent transport of those gases with a structure. Propane gas burner fire experiments were conducted in a purpose-built two-story structure instrumented to measure temperature, pressure, velocity, and gas concentrations. Experiments were conducted to assess heat and gas species transfer due to HVAC operating status (off vs. on), fire location and heat release rate, and bedroom door position (open vs. closed). (c) 2022 The Author(s). Published by Elsevier Inc.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.1
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据