4.2 Review

Diagnostic performance of MRI for prediction of recurrent prostate cancer after high-intensity focused ultrasound: a systematic review and meta-analysis

期刊

PROSTATE INTERNATIONAL
卷 11, 期 2, 页码 59-68

出版社

ELSEVIER INC
DOI: 10.1016/j.prnil.2022.12.004

关键词

High-intensity focused ultrasound ablation; Local neoplasm recurrence; Magnetic resonance imaging; Meta-analysis; Prostate neoplasms; Systematic review

向作者/读者索取更多资源

This study evaluated the diagnostic performance of MRI in predicting recurrent prostate cancer after high-intensity focused ultrasound (HIFU). Nineteen studies including 703 patients were included in the analysis. The results showed that MRI had adequate diagnostic performance for predicting PCa recurrence after HIFU, but the results may have been exaggerated.
Purpose: This article aims to evaluate the pooled diagnostic performance control MRI for prediction of recurrent prostate cancer (PCa) after high-intensity focused ultrasound (HIFU). Materials and methods: MEDLINE, EMBASE, and Cochrane library databases up to December 31, 2021, were searched. We included studies providing 2x2 contingency table for diagnostic performance of MRI in predicting recurrent PCa after HIFU, using control biopsy as reference standard. The quality of the included studies was assessed using Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2). Sensitivity and specificity were pooled and displayed in a summary receiver operating characteristics (SROC) plot. Meta-regression analysis using clinically relevant covariates was performed for the causes of heterogeneity. Results: Nineteen studies (703 patients) were included. All included studies satisfied at least four of the seven QUADAS-2 domains. Pooled sensitivity was 0.81 (95% CI 0.72-0.90) with specificity of 0.91 (95% CI 0.86-0.96), with area under the SROC curve of 0.81. Larger studies including more than 50 patients showed relatively poor sensitivity (0.68 vs. 0.84) and specificity (0.75 vs. 0.93). The diagnostic performance of studies reporting higher nadir serum prostate-specific antigen levels (>1 ng/mL) after HIFU was inferior, and differed significantly in sensitivity (0.54 vs. 0.78) rather than specificity (0.85 vs. 0.91). Conclusions: Although MRI showed adequate diagnostic performance in predicting PCa recurrence after HIFU, these results may have been exaggerated. (c) 2023 The Asian Pacific Prostate Society. Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据