4.7 Article

One-Step Fabrication of Paper-Based Inkjet-Printed Graphene for Breath Monitor Sensors

期刊

BIOSENSORS-BASEL
卷 13, 期 2, 页码 -

出版社

MDPI
DOI: 10.3390/bios13020209

关键词

breath monitoring; capacitive sensors; graphene ink; inkjet printing; paper sensor; relative humidity sensor

向作者/读者索取更多资源

Irregularities in breathing patterns can be predicted with the help of breath monitor sensors that detect variations in humidity during inhalation and exhalation. Graphene-based RH sensors show excellent sensitivity, stability, and repeatability. By embedding the sensor into a face mask and interfacing it with a microcontroller, different breathing situations can be measured, making it a promising wearable and disposable healthcare technology.
Irregularities in breathing patterns can be detected using breath monitor sensors, and this help clinicians to predict health disorders ranging from sleep disorders to heart failures. Variations in humidity during the inhalation and exhalation of breath have been utilized as a marker to detect breath patterns, and graphene-based devices are the favored sensing media for relative humidity (RH). In general, most graphene-based RH sensors have been used to explore resistance change as a measurement parameter to calibrate against the RH value, and they are prone to noise interference. Here, we fabricated RH sensors using graphene ink as a sensing medium and printed them in the shape of interdigital electrodes on glossy paper using an office inkjet printer. Further, we investigated the capacitance change in the sensor for the RH changes in the range of 10-70%. It exhibited excellent sensitivity with 0.03 pF/% RH, good stability, and high intraday and interday repeatability, with relative standard deviations of 1.2% and 2.2%, respectively. Finally, the sensor was embedded into a face mask and interfaced with a microcontroller, and capacitance change was measured under three different breathing situations: normal breathing, deep breathing, and coughing. The result show that the dominant frequency for normal breath is 0.22 Hz, for deep breath, it is 0.11 Hz, and there was no significant dominant cough frequency due to persistent coughing and inconsistent patterns. Moreover, the sensor exhibited a short response and recovery time (<5 s) during inhalation and exhalation. Thus, the proposed paper-based RH sensor is promising wearable and disposable healthcare technology for clinical and home care health applications.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据