4.7 Article

Picosecond laser-assisted synthesis of silver nanoparticles with high practical application as electroanalytical sensor

期刊

SURFACES AND INTERFACES
卷 35, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.surfin.2022.102464

关键词

Pulsed laser ablation in liquids; Silver nanoparticles; Modified screen-printed carbon electrode; Gallic acid

资金

  1. Ministry of Education, Science and Technological Development of the Republic of Serbia [451-03-68/2022-14/200017, E! 13303 MED-BIO-TEST]

向作者/读者索取更多资源

Gallic acid is an important natural phenolic compound with well-known biological properties. This study successfully prepared silver nanoparticles using pulsed laser ablation technique and used them to modify carbon electrodes for the detection of gallic acid. A differential pulse voltammetric protocol was developed for accurate measurement of gallic acid and its antioxidant capacity.
Gallic acid (GA) is one of the most important and present natural phenolic compounds due to its well-known biological properties, and its detection and monitoring is of great importance. Silver nanoparticles (AgNPs) are one of the most studied metallic nanomaterials used in various fields, from biomedical applications to electrochemical sensing devices. In this work, we used the pulsed laser ablation technique in liquid for the onestep preparation of nanoparticles of silver from a pure silver plate base in N,N-dimethylformamide. Obtained nanomaterial was characterized using morphological and electrochemical methods and used for modification of screen-printed carbon electrodes (SPCE). Successful immobilization at the surface is confirmed using the surface profiling method. A newly obtained sensor was used for the detection of GA. After parameters optimization, a differential pulse voltammetric protocol was developed, using two approaches - concentration vs. current (GA determination) and peak area vs. current (estimation of the antioxidant capacity). For the first approach sensor linearity was found to be in the range from 0.50 mu M to 10 mu M, with the limit of detection (LOD) of 0.16 mu M and limit of quantification (LOQ) of 0.50 mu M. In the second system operating linear range was the same, while LOD and LOQ were 0.11 mu M and 0.34 mu M, respectively. Practical application of the method was tested using two approaches: direct measurement of gallic acid in biological fluids and estimation of the antioxidant capacity and food quality purpose.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据