4.5 Article

New insight: particle flow rate from the airways as an indicator of cardiac failure in the intensive care unit

期刊

ESC HEART FAILURE
卷 10, 期 1, 页码 691-698

出版社

WILEY PERIODICALS, INC
DOI: 10.1002/ehf2.14242

关键词

Cardiac failure; Particle flow rate; Cardiac surgery; Mechanical ventilation; Particle mass

向作者/读者索取更多资源

Exhaled breath particles may be used to detect cardiac failure, as patients with post-operative cardiac failure following surgery exhibit increased particle mass and flow rate compared to those without cardiac failure. Impaired cardiac function is also associated with differences in particle composition.
AimsExhaled breath particles have been explored for diagnosing different lung diseases. We recently showed in an experimental model that different cardiac output results in different particle flow rate (PFR) from the airways. Given the well-known close relationship between impaired cardiac function and respiratory failure, we hypothesized that PFR in exhaled air can be used to detect cardiac failure. MethodsPFR was analysed using a customized PExA device. Particles in the range of 0.41-4.55 mu m were measured. The included patients (n = 20) underwent cardiac surgery and received mechanical ventilation as a part of routine post-operative care. Ten patients with clinical signs of pronounced post-operative haemodynamic instability and need for inotrope or mechanical support had been selected to the cardiac failure group. The control group consisted of 10 patients without signs of cardiac failure. ResultsThe patients in cardiac failure group required inotropic support in the form of dobutamine (9/10), epinephrine (2/10), or levosimendan (4/10) or use of an intra-aortic balloon pump (4/10). There was no use of inotropes or mechanical support devices among the controls. All patients in the cardiac failure group had pre-operative left ventricular ejection fraction <= 40% compared with the control group, whose pre-operative ejection fraction was >= 50%, P < 0.001. Patients with cardiac failure had significantly longer median total time in mechanical ventilation compared with the patients in the control group: 53.5 h (IQR 6.8-116101.0 h) and 4.5 h (IQR 4.0-5.5 h), respectively, P < 0.001, and the median length of stay in the ICU, 165 h (IQR 28-192 h) and 22 h (IQR 20-23.5 h), respectively, P = 0.007. Median PFR in patients with cardiac failure was higher than PFR in those with normal cardiac function: 80.9 particles/min (interquartile range (IQR) 25.8-336.6 particles/min), vs. 15.3 particles/min (IQR 8.1-17.7 particles/min), respectively, P < 0.001. Median particle mass was 8.95 ng (IQR 1.68-41.73 ng) in the cardiac failure group and 0.75 ng (IQR 0.18-1.45 ng) in the control group, P = 0.002. ConclusionsPatients with post-operative cardiac failure following cardiac surgery exhibited an increase in exhaled particle mass and PFR compared with the control group, indicating a significant difference between those two groups. The increase in particle mass and PFR in the absence of respiratory pathologies may indicate cardiac failure. In comparison with controls, impaired cardiac function was also associated with different composition of the particles regarding their size distribution.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据