4.3 Article

Influence of Pachymetry and Intraocular Pressure on Dynamic Corneal Response Parameters in Healthy Patients

期刊

JOURNAL OF REFRACTIVE SURGERY
卷 32, 期 8, 页码 550-561

出版社

SLACK INC
DOI: 10.3928/1081597X-20160524-01

关键词

-

资金

  1. Oculus Optikgerate GmbH
  2. National Institutes of Health Research (NIHR) [II-LS-1010-10007] Funding Source: National Institutes of Health Research (NIHR)
  3. EPSRC [EP/H052046/1, EP/N014499/1] Funding Source: UKRI
  4. Engineering and Physical Sciences Research Council [EP/N014499/1, EP/H052046/1] Funding Source: researchfish
  5. National Institute for Health Research [HTD 539, II-LS-1010-10007] Funding Source: researchfish

向作者/读者索取更多资源

PURPOSE: To evaluate the influence of pachymetry, age, and intraocular pressure in normal patients and to provide normative values for all dynamic corneal response parameters (DCRs) provided by dynamic Scheimpflug analysis. METHODS: Seven hundred five healthy patients were included in this multicenter retrospective study. The biomechanical response data were analyzed to obtain normative values with their dependence on corrected and clinically validated intraocular pressure estimates developed using the finite element method (bIOP), central corneal thickness (CCT), and age, and to evaluate the influence of bIOP, CCT, and age. RESULTS: The results showed that all DCRs were correlated with bIOP except deflection amplitude (DefA) ratio, highest concavity (HC) radius, and inverse concave radius. The analysis of the relationship of DCRs with CCT indicated that HC radius, inverse concave radius, deformation amplitude (DA) ratio, and DefA ratio were correlated with CCT (rho values of 0.343, -0.407, -0.444, and -0.406, respectively). The age group subanalysis revealed that primarily whole eye movement followed by DA ratio and inverse concave radius were the parameters that were most influenced by age. Finally, custom software was created to compare normative values to imported examinations. CONCLUSIONS: HC radius, inverse concave radius, DA ratio, and DefA ratio were shown to be suitable parameters to evaluate in vivo corneal biomechanics due to their independence from IOP and their correlation with pachymetry and age. The creation of normative values allows the interpretation of an abnormal examination without the need to match every case with another normal patient matched for CCT and IOP.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据