4.6 Article Proceedings Paper

Data-driven assessment for the supervision of District Heating Networks

期刊

ENERGY REPORTS
卷 8, 期 -, 页码 34-40

出版社

ELSEVIER
DOI: 10.1016/j.egyr.2022.10.212

关键词

District Heating; Energy System; Low temperature district heating; Temperature reduction; Case study; Network Operation; Heat supply; Infrastructure improvement; Thermal substation; Heat Meter

资金

  1. European Union [768567]
  2. H2020 Societal Challenges Programme [768567] Funding Source: H2020 Societal Challenges Programme

向作者/读者索取更多资源

Recently, there has been a trend towards reducing temperatures in district heating networks to improve sustainability. However, there is still insufficient knowledge on how to successfully transition to a low temperature district heating system while maintaining operational levels. This paper presents the experience of gradually reducing temperatures in a district heating subnetwork in Tartu, Estonia from 2018 to 2021. Heat meter data was used extensively to assess the capacity of substations and network branches, leading to targeted improvements and interventions. The ongoing process has shown a 4.8% reduction in network heat loss through a temperature decrease of 7 degrees Celsius.
There is an ongoing trend towards temperature reduction in District Heating Networks, allowing for the reduction of distribution heat loss and enabling the integration of low exergy heat production systems. There is a clear scientific consensus on the improved sustainability of such systems. However, there is not sufficient knowledge on how to deliver a successful transition to a low temperature District Heating system, while ensuring the operational levels of the existing system. This paper presents the experience on the progressive temperature reduction of a district heating subnetwork over the 2018-2021 period in Tartu, Estonia. Data from heat meters is extensively used to assess the capacity of substations and network branches to deliver the required heat and quality levels. Faulty substations are identified for targeted assessment and improvement works. Several substations have been identified as missing some of the performance criteria. This has led to further analysis, closer supervision and interventions in the operational conditions of the network. This is an ongoing process, expected to remain in the established procedures of the DH network operator. At the end of the process, a temperature reduction of 7 degrees C has shown an improvement of 4.8% in network heat loss. (C) 2022 The Author(s). Published by Elsevier Ltd.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据