4.6 Article

Multicenter Diagnostic Evaluation of a Novel Coronavirus Antigen Lateral Flow Test among Symptomatic Individuals in Brazil and the United Kingdom

期刊

MICROBIOLOGY SPECTRUM
卷 10, 期 6, 页码 -

出版社

AMER SOC MICROBIOLOGY
DOI: 10.1128/spectrum.02012-22

关键词

diagnostics; COVID-19; SARS-CoV-2; LFA; Ag-RDT

资金

  1. NIHR Clinical Research Network (CRN)
  2. Unitaid [2019-32-FIND MDR]
  3. government of the Netherlands [MINBUZA-2020.961444]
  4. UK Department for International Development [300341-102]

向作者/读者索取更多资源

This report presents the clinical evaluation of the Hotgen Antigen Test in Brazil and the UK, with an overall sensitivity of 88.2% and specificity of 100%. The test meets the minimum performance requirements set by the WHO for COVID-19 antigen tests.
The COVID-19 pandemic has led to the commercialization of many antigen-based rapid diagnostic tests (Ag-RDTs), requiring independent evaluations. This report describes the clinical evaluation of the Novel Coronavirus 2019-nCoV Antigen Test (Colloidal Gold) (Beijing Hotgen Biotech Co., Ltd.), at two sites within Brazil and one in the United Kingdom. The collected samples (446 nasal swabs from Brazil and 246 nasopharyngeal samples from the UK) were analyzed by the Ag-RDT and compared to reverse transcription-quantitative PCR (RT-qPCR). Analytical evaluation of the Ag-RDT was performed using direct culture supernatants of SARS-CoV-2 strains from the wild-type (B.1), Alpha (B.1.1.7), Delta (B.1.617.2), Gamma (P.1), and Omicron (B.1.1.529) lineages. An overall sensitivity and specificity of 88.2% (95% confidence interval [CI], 81.3 to 93.3) and 100.0% (95% CI, 99.1 to 100.0), respectively, were obtained for the Brazilian and UK cohorts. The analytical limit of detection was determined as 1.0 x 10(3) PFU/mL (Alpha), 2.5 x 10(2) PFU/mL (Delta), 2.5 x 10(3) PFU/mL (Gamma), and 1.0 x 10(3) PFU/mL (Omicron), giving a viral copy equivalent of approximately 2.1 x 10(4) copies/mL, 9.0 x 10(5) copies/mL, 1.7 x 10(6) copies/mL, and 1.8 x 10(5) copies/mL for the Ag-RDT, respectively. Overall, while a higher sensitivity was claimed by the manufacturers than that found in this study, this evaluation finds that the AgRDT meets the WHO minimum performance requirements for sensitivity and specificity of COVID-19 Ag-RDTs. This study illustrates the comparative performance of the Hotgen Ag-RDT across two global settings and considers the different approaches in evaluation methods.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据