4.7 Article

Suitability of Raycell MK2 Blood X-ray Irradiator for the Use in the Sterile Insect Technique: Dose Response in Fruit Flies, Tsetse Flies and Mosquitoes

期刊

INSECTS
卷 14, 期 1, 页码 -

出版社

MDPI
DOI: 10.3390/insects14010092

关键词

Ceratitis capitata; Anastrepha ludens; Glossina palpalis gambiensis; Aedes aegypti; Anopheles arabiensis; X-ray; gamma ray; sterility; SIT

向作者/读者索取更多资源

The sterile insect technique (SIT) is an environmentally friendly and species-specific method of pest control that involves mass production of target insects in a factory and sterilizing them using irradiation, typically gamma rays. As gamma sources become more difficult and expensive to obtain, and regulations surrounding their use become stricter, there is growing interest in alternative irradiation methods such as X-rays. A recent study found that X-rays can be used effectively to sterilize major SIT target insect species, making X-ray units suitable for small-to-medium-sized SIT programs.
Simple Summary The sterile insect technique (SIT) is an environment-friendly, species-specific pest control method by which target insects are mass-produced in a factory and are made infertile by irradiation-usually with gamma rays. However, gamma sources are becoming more difficult and expensive to purchase, and the regulations surrounding these types of irradiators are becoming stricter. Therefore, there is now increasing interest in alternatives, such as X-ray irradiators. Following a recent technical evaluation of a blood X-ray unit, the aim of this research was to assess the biological responses of a selection of major SIT target insect species to irradiation in the X-ray unit as compared to gamma ray irradiation. It was found that all the insects responded similarly to X-rays as to gamma rays and that the X-ray unit is suitable for small- to medium-sized SIT programs. The sterile insect technique (SIT) is based on the inundatory field release of a target pest following their reproductive sterilization via exposure to radiation. Until recently, gamma irradiation from isotopic sources has been the most widely used in SIT programs. As isotopic sources are becoming increasingly expensive, especially for small programs, and regulations surrounding their procurement and shipment increasingly strict, irradiation capacity is one of the limiting factors in smaller or newly developing SIT projects. For this reason, the possibility of using X-ray irradiators has been evaluated in the recent decade. The availability of off-the-shelf blood X-ray irradiators that meet the technical requirements for insect irradiation can provide irradiation capacity for those SIT projects in which the acquisition of gamma ray irradiators is not feasible. Following the recent technical characterization of a Raycell MK2 X-ray blood irradiator, it was found in this study, that MK2 instruments were suitable for the sterilization of fruit flies, tsetse flies and mosquitoes, inducing comparable, even slightly higher, sterility levels compared to those achieved by gamma ray irradiation. This, together with its estimated processing efficiency, shows that MK2 irradiators are suitable for small- to mid-sized SIT programs.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据