4.7 Article

Safety and immunogenicity of a bivalent SARS-CoV-2 protein booster vaccine, SCTV01C, in adults previously vaccinated with mRNA vaccine: a randomized, double-blind, placebo-controlled phase 1/2 clinical trial

期刊

EBIOMEDICINE
卷 87, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.ebiom.2022.104386

关键词

Safety; Immunogenicity; SARS-CoV-2; Bivalent protein vaccine; Booster; SCTV01C

向作者/读者索取更多资源

This study aimed to evaluate the safety and immunogenicity of SCTV01C, a novel bivalent protein vaccine, as a booster for individuals who previously received two doses of mRNA vaccine. The results showed that SCTV01C vaccine had high cross-neutralizing antibody responses against Delta and Omicron variants, and was well-tolerated.
Background Booster vaccination is an efficient way to address the waning protection of vaccines and immune escape of SARS-CoV-2 variants. We aimed to assess the safety and immunogenicity of SCTV01C, a novel bivalent protein vaccine as a booster for people who previously received two doses of mRNA vaccine.Methods In this randomized, phase 1/2 trial, adults fully vaccinated with mRNA vaccines 3-24 month earlier were enrolled. Participants received SCTV01C at 20 mu g, 40 mu g or placebo. The primary endpoints were adverse reactions within 7 days and immunogenicity on Day 28 after vaccination. This trial was registered with ClinicalTrials.gov (NCT05043311).Findings Between January 27 and April 28, 2022, 234 adults were randomly assigned to receive SCTV01C or placebo. The most common solicited adverse events (AEs) were Grade 1 injection-site pain (10.7%) and pyrexia (6.3%). There were no reports of Grade 3 or above solicited AE, serious AEs or AEs of special interests. On Day 28 post the booster, the geometric mean concentrations (GMCs) of the specific binding IgG antibodies to spike protein for placebo, 20 mu g and 40 mu g SCTV01C were 1649, 4153 and 5354 BAU/mL, with fold of increase from baseline of 1.0, 2.8 and 3.4-fold, respectively. GMTs of neutralizing antibodies against live Delta variant were 1280, 3542, and 4112, with fold of increase of 1.1, 3.9 and 4.1-fold, respectively; GMTs of neutralizing antibodies against live Omicron variant were 218, 640, and 1083, with fold of increase of 1.1, 4.4 and 5.1-fold, respectively. Participants with low neutralizing antibody titers at baseline (below the lower limit of quantitation) had 64.0 and 49.4-fold of increase in GMTs for Delta and Omicron, respectively. Interpretation The heterologous booster of SCTV01C was safe, and induced uniformly high cross-neutralization antibody responses against Delta and Omicron variants. Copyright (c) 2022 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据