4.5 Article

Early Assessment of Circumferential Anterior Segment Structures Following Implantable Collamer Lens V4c Implantation Via SS-OCT

期刊

出版社

ASSOC RESEARCH VISION OPHTHALMOLOGY INC
DOI: 10.1167/tvst.11.11.4

关键词

circumferential anterior segment structure; implantable collamer lens V4c; swept-source optical coherence tomography

资金

  1. National Natural Science Foundation of China [81770955]
  2. Joint Research Project of New Frontier Technology in Municipal Hospitals [SHDC12018103]
  3. Project of Shanghai Science and Technology [20410710100]
  4. Clinical Research Plan of SHDC [SHDC2020CR1043B]
  5. Project of Shanghai Xuhui District Science and Technology [2020-015]
  6. Shanghai Municipal Commission of Health and Family Planning [202040285]

向作者/读者索取更多资源

The study investigated early changes in circumferential anterior segment structures after ICL V4c implantation, providing a better understanding of the characteristics of anterior segment structures after ICL V4c surgery.
Purpose: To explore early changes in circumferential anterior segment structures following Implantable Collamer Lens (ICL) V4c implantation via swept-source optical coherence tomography (SS-OCT).Methods: In 103 eyes of 56 myopic patients undergoing ICL V4c surgery, anterior segments were measured via SS-OCT to compute local anterior chamber angle (ACA) parameters on the nasal-temporal (0 degrees-180 degrees), superior-inferior (90 degrees-270 degrees), and superior nasal-inferior temporal (80 degrees-260 degrees) meridians, including angle-opening distance at 500 pm (AOD500), trabecular-iris space area at 500 pm (TISA500), trabecular-iris angle at 500 pm (TIA500), and circumferential ACA parameters, including AOD area at 500 pm (AODA500), trabecular-iris circumference volume at 500 pm (TICV500), and the index and area of iris-trabecular contact (ITC). ACA parameters were compared preoperatively and at 1 week, 1 month, and 3 months postoperatively and compared among quadrants. Mixed-effects model was used to evaluate the parameters correlated with the post-ITC parameters.Results: The mean AOD500, TISA500, TIA500, AODA500, and TICV500 were decreased by 65.4% to 71%, 64.1% to 69.3%, 53.8% to 61.5%, 69.9%, and 69.2%, respectively, at 1 week postoperatively. The ITC index and area values rose from 1.436% +/- 4.427% and 0.070 +/- 0.254 mm2 to 12.343% +/- 13.216% and 0.903 +/- 1.304 mm2 (all P < 0.05). No further decreases in ACA parameters were observed beyond 1 week postoperatively (all P > 0.05). Significant differences were observed among quadrants, with the narrowest in the superior-nasal quadrant, followed by the superior quadrant. The 3-month vault was significantly correlated with the ITC index and area at 3 months postoperatively.Conclusions: Anterior segment structures were significantly shallow at 1 week with no further decreases thereafter. In light of anatomical variability, we recommend circumfer-ential meridian scan to assess angle status, with special attention to the superior-nasal and superior quadrants.Translational Relevance: We investigated the early changes in circumferential anterior segment structures following ICL V4c implantation, thus providing a better perspective for understanding anterior segment structural characteristics after ICL V4c surgery.