4.6 Article

Cucurbituril-assisted sensitive fluorescence detection and quantitation of naproxen drug in wastewater samples: Guest-host characterization and HPLC investigation

期刊

FRONTIERS IN CHEMISTRY
卷 10, 期 -, 页码 -

出版社

FRONTIERS MEDIA SA
DOI: 10.3389/fchem.2022.1093231

关键词

naproxen; cucurbituril; fluorescence; guest-host interaction; wastewater

资金

  1. Research Office of the United Arab Emirates University [31S281]

向作者/读者索取更多资源

In this study, sensitive spectrofluorometry and liquid chromatography with fluorescence detection were used to detect and determine the naproxen drug, and it was found that the addition of cucurbit7uril (CB7) improved the fluorescence signals. The guest-host interaction between naproxen and cucurbiturils was investigated using fluorescence spectroscopy, mass spectrometry, H-1-NMR, and liquid chromatography with fluorescence detection. It was discovered that naproxen formed a supramolecular complex with CB7, and the optimal conditions for the interaction were determined. HPLC with a fluorescence detector was then used to detect naproxen in wastewater samples by sample enrichment. The measured concentrations of naproxen in the influent and effluent wastewater were determined.
Sensitive spectrofluorometric and liquid chromatography with fluorescence detection methods have been developed for detection and determination of naproxen drug in the presence of cucurbit7uril (CB7). Fluorescence signals have been improved with the addition of CB7 to the drug aqueous solution. Fluorescence spectroscopy, mass spectrometry, H-1-NMR, and liquid chromatography with fluorescence detection were used to investigate the guest-host interaction of naproxen drug and cucurbiturils. Naproxen was found to form a supramolecular complex with CB7 that had a high formation constant. The optimal conditions for the interaction were discovered using spectroflurometry to be 0.2 mg/ml of CB7, 2.4 mu g/ml of naproxen drug, and pH10. A 1:1 complex between naproxen and CB7 is revealed by proton NMR and tandem mass spectrometry. Using the standard addition calibration method, an HPLC with a fluorescence detector was used to detect naproxen in influent and effluent wastewater samples. Finally, it was discovered that the measured concentrations of naproxen in the influent and the effluent wastewater were 1.87 x 10(-4) ppb and 2.1 x 10(-5) ppb, respectively. This was done by sample enrichment, which reduced the 1000 mL into 1 ml.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据