4.5 Article

Comparison of experience curves between two 3-dimensional intraoral scanners

期刊

JOURNAL OF PROSTHETIC DENTISTRY
卷 116, 期 2, 页码 221-230

出版社

MOSBY-ELSEVIER
DOI: 10.1016/j.prosdent.2015.12.018

关键词

-

资金

  1. Basic Science Research Program through National Research Foundation of Korea
  2. Ministry of Science, Information and Communications Technologies and Future Planning grant [2013R1A1A1076022]
  3. National Research Foundation of Korea [2013R1A1A1076022] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

向作者/读者索取更多资源

Statement of problem. Conventional impression-making methods are being replaced by intraoral digital scanning. How long dental professionals take to master the new technologies is unknown. Purpose. The purpose of this human subject study was to compare the experience curves of 2 intraoral scanners among dental hygienists and determine whether repeated scanning experience could change the scan time (ST). Material and methods. A total of 29 dental hygienists with more than 3 years of working experience were recruited (group 1: 3-5 years; group 2: >6 years of clinical experience) to learn the iTero and Trios systems. All learners scanned the oral cavities of 4 human participants (participants A, B, C, and D) 10 times (T1-T10) throughout the learning sessions and the experimental dentoform model twice at the beginning and end of the 10 sessions. ST was measured, and changes in ST were compared between the 2 devices. Results. The average ST for 10 sessions was greater with iTero than with Trios, but the decrease in the measured ST was greater for iTero than for Trios. Baseline and postexperience STs with iTero showed statistically significant differences, with a decrease in time related to the clinical experience levels of the dental hygienists (group 1: T2 and T4, P<.01; group 2:T2 and T5, P<.01). The experience curve with iTero was not influenced by the human participant's intraoral characteristics, and greater ST was shown for participants B and C than for participants A and D with Trios. Conclusions. Although the learning rate of iTero was rapid, the average ST for iTero was longer than Trios, and clinical experience levels influenced the operator's ability to manipulate the device. In contrast, the learning rate of Trios was slow, and measured ST was shorter than iTero, and was not influenced by clinical experience.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据