Microstructure, Shape Memory Effect, Chemical Composition and Corrosion Resistance Performance of Biodegradable FeMnSi-Al Alloy

期刊

CRYSTALS
卷 13, 期 1, 页码 -

出版社

MDPI
DOI: 10.3390/cryst13010109

关键词

biodegradable; SME; FeMnSi; SEM; EDS; EIS

向作者/读者索取更多资源

Researchers have focused on the medical applications of degradable iron-based biomaterials due to their unique properties acquired through alloying with various elements and different technological methods. Iron-based alloys are particularly designed for low production costs, non-magnetism through alloying with Mn, and shape memory effect through alloying with Si, making them promising alternatives to nitinol in medical applications. This paper investigates the FeMnSi-Al alloy as a biodegradable material and examines its phases using X-ray diffraction, shape memory effect using differential scanning calorimetry, and corrosion rate through in vitro tests and electrochemical techniques.
The medical applications of degradable iron-based biomaterials have been targeted by re-searchers due to their special properties that they present after alloying with various elements and different technological methods of obtaining. Compared to other biodegradable materials, iron-based alloys are designed especially for the low production costs, the non-magnetism obtained by alloying with Mn, and the shape memory effect (SME) following the alloying with Si, which is necessary in medical applications for which it could replace nitinol successfully. Alloying with new elements could improve the mechanical properties, the degradation rate, and the transformation temperatures corresponding to the SME. This paper presents the results from the study of FeMnSi-Al alloy as a biodegradable material. The X-ray diffraction (XRD) method was used to identify the phases formed in the experimental Fe-Mn-Si-Al alloy, and the SME was studied by differential scanning calorimetry (DSC). In vitro tests were performed by immersing the samples in Ringer's biological solution for different time intervals (1, 3, and 7 days). The chemical composition of the samples, as well as the compounds resulting from the immersion tests, were evaluated by energy dispersive X-ray (EDS). Scanning electron microscopy (SEM) was used for the microstructural analysis and for highlighting the surfaces subjected to contact with the electrolyte solution. The corrosion rate (CR, mm/yr.) was calculated after mass loss, sample surface area, and immersion time (h) (at 37 degrees C). Samples were subjected to electro-corrosion tests using electrochemical impedance spectroscopy (EIS) and Tafel linear and cyclic potentiometry.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据