4.6 Article

Which sites better represent the sensory function of hands in convalescent stroke patients? A study based on electrophysiological examination

期刊

FRONTIERS IN NEUROSCIENCE
卷 16, 期 -, 页码 -

出版社

FRONTIERS MEDIA SA
DOI: 10.3389/fnins.2022.1065629

关键词

stroke; sensory; SEP; light touch sensation; 2-PD

向作者/读者索取更多资源

This study aimed to explore the nature of light touch sensation and two-point discrimination (2-PD) of different hand sites in convalescent stroke patients based on somatosensory evoked potentials (SEP). The results showed that light touch sensation was mainly associated with sensory impairment in the finger and palm region. Two-point discrimination in the finger region was mainly sensory loss, while in the palm region it was mainly sensory impairment. Any site on the hand could be selected as the measurement site for light touch sensation, but the little finger and hypothenar may be appropriate sites when screening for 2-PD.
BackgroundAssessing hand sensation in stroke patients is necessary; however, current clinical assessments are time-consuming and inaccurate. ObjectiveThis study aimed to explore the nature of light touch sensation and two-point discrimination (2-PD) of different hand sites in convalescent stroke patients based on somatosensory evoked potentials (SEP). MethodsLight touch sensation and 2-PD of the thumb, the index finger, the little finger, thenar, and hypothenar were measured (n = 112) using sensory measurement tools. Sensory differences among the hand sites were then compared. The correlation analysis between SEP and the hemiplegic hand function was made. Sensory functions were divided into three levels: sensory intactness, sensory impairment, and sensory loss. ResultsLight touch sensations were mainly associated with sensory impairment in the finger and palm region. The 2-PD of the finger region was mainly sensory loss and that of the palm region was mainly sensory impairment. There was no statistical difference in the light touch sensation among the sites of the hand. The correlation coefficients between the 2-PD and SEP N20 amplitudes differed. The correlation coefficients of the thenar and hypothenar were the smallest, and that of the finger was the largest. Light touch sensation and 2-PD in patients with stroke were related to the hemiplegic hand function. ConclusionAny site on the hand could be selected as the measurement site for light touch sensation. The little finger and hypothenar may be appropriate sites when screening for 2-PD. To improve the patient's recovery they could receive more sensory stimulation of the hand.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据