Copper Sulfate-Induced Diphenylamine for Rapid Colorimetric Point-of-Care Detection of Contagious Pathogens Combined with Loop-Mediated Isothermal Amplification

期刊

出版社

AMER CHEMICAL SOC
DOI: 10.1021/acssuschemeng.2c04726

关键词

diphenylamine; copper sulfate; colorimetric detection; foldable microdevice; contagious pathogens

向作者/读者索取更多资源

We developed a colorimetric strategy based on copper sulfate (CuSO4)-initiated diphenylamine (DPA) coupled with loop-mediated isothermal amplification (LAMP) for rapid detection of SARS-CoV-2 and Enterococcus faecium. Acid hydrolysis of LAMP amplicons was used to detect the DNA and generate a blue color. The method successfully detected low quantities of SARS-CoV-2 RNA and E. faecium, indicating its advantages. Multiplex detection of pathogens was performed using a foldable microdevice, confirming the practical applicability of the method.
Here, we developed a copper sulfate (CuSO4)-initiated diphenylamine (DPA)-based colorimetric strategy coupled with loop-mediated isothermal amplification (LAMP) for rapid detection of two critical contagious pathogens, SARS-CoV-2 and Enterococcus faecium. To detect the DNA, acid hydrolysis of LAMP amplicons was executed, enabling the development of a blue color. In the LAMP amplicons, the bond between the purines and deoxyribose is extremely labile. It can be broken using 70% sulfuric acid followed by phosphate group elimination, which generates a highly active keto aldehyde group. CuSO4 plays an imperative role inducing DPA to rapidly react with the keto aldehyde group, producing an intense blue color within 5 min. Moreover, low quantities such as 103 copies mu L-1 of SARS-CoV-2 RNA and 102 CFU mL-1 of E. faecium were successfully detected, revealing the advantages of the introduced method. To confirm practical applicability, multiplex detection of pathogens was performed using a foldable microdevice comprising reaction and detection zones. Various reactions such as DNA extraction, LAMP, and acid hydrolysis occurred in the reaction zone. Then, colorimetric reagents (DPA, CuSO4, and ethylene glycol) contained in the detection zone were mixed with the keto aldehyde group by simply folding the microdevice, which was heated at 65 degrees C for 5 min for colorimetric detection. An intense blue color was developed where the target DNA was present. These results indicate that the method proposed in this study is highly suitable for point-of-care applications, especially in resource-limited settings for the rapid detection of harmful pathogens.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据