4.3 Article

Effect of finish line location and saliva contamination on the accuracy of crown finish line scanning

出版社

WILEY
DOI: 10.1111/jopr.13658

关键词

digital impression accuracy; gingival retraction; saliva contamination

向作者/读者索取更多资源

The purpose of this study was to evaluate the influence of finish line location and saliva contamination on the scanning trueness of crown finish lines. The results showed that subgingival finish lines had greater discrepancies and saliva contamination significantly reduced scanning trueness, especially for the subgingival groups.
PurposeIntraoral scanners are used widely as an alternative to conventional impressions, but studies on the influence of finish line location and saliva contamination on scanning trueness are lacking. The purpose of this in vitro study was to evaluate the influence of finish line location and saliva contamination on the scanning trueness of crown finish lines. Materials and methodsThree ivorine teeth were prepared for all-ceramic crowns with finish lines placed equigingivally, 0.5 mm subgingivally, and 1.0 mm subgingivally. A single-cord technique was used for gingival retraction, and a total of 180 intraoral scans were made using two intraoral scanners (Emerald; Planmeca USA Inc., Hoffman Estates, IL, USA & Trios 3; 3Shape A/S, Copenhagen, Denmark). The prepared teeth were separated from the dentoform and scanned using the same intraoral scanners to create reference scans. All scans were imported to the design software (Dental System 2019; 3Shape A/S, Copenhagen, Denmark). After marking the finish lines of prepared teeth, intraoral scans were aligned to the reference scans for comparisons. Vertical and horizontal marginal discrepancies were measured at four different measuring points (buccal, lingual, mesial, and distal) and analyzed. Two-way ANOVA and Tukey HSD tests were used for statistical analysis (alpha = 0.05). ResultsThe average vertical and horizontal discrepancies from various groups ranged from -33 to 440 mu m. For both intraoral scanners, subgingival finish line groups showed greater vertical and horizontal discrepancies compared with equigingival finish line groups. Saliva contamination significantly increased both vertical and horizontal discrepancies for all finish line locations. The discrepancy increases due to saliva contamination were greater for the subgingival groups. ConclusionsSubgingival finish lines were not accurately captured using the intraoral scanners. The presence of saliva significantly reduced scanning trueness, and this was amplified when the finish lines were located subgingivally.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据