This study compared the closure strengths and leak pressures of the PSS and OTSC techniques in an ex vivo porcine model. The results showed that OTSC demonstrated greater closure strength and leak pressure compared to PSS. However, further research is needed to develop a suitable therapeutic strategy for larger defects due to the size limitations of OTSC.
BackgroundThe recently developed endoscopic full-thickness resection technique requires reliable closure. The main closure methods are the purse-string suture (PSS) technique and over-the-scope clip (OTSC) technique; however, basic data on the closure strength of each technique are lacking. This study was performed to compare the closure strengths of these two methods in an ex vivo porcine model.MethodsIn the traction test, a virtual 5-cm full-thickness closure line was closed by the following six methods three times each: conventional hemoclips, mucosal PSS, seromuscular PSS, mucosal OTSC, seromuscular OTSC, and surgical suture. The primary endpoint was the tension at the starting point of dehiscence, measured in Newtons (N) by an automatic traction machine. In the leak test, a 15-mm gastric full-thickness defect was closed by PSS or OTSC six times each, and the closed stomach was then pressurized in a water container. The primary endpoint was the leak pressure when air bubbles appeared. The secondary endpoints were the procedure time and presence of complete inverted closure.ResultsThe mean tension was 2.16, 3.68, 5.15, 18.30, 19.30, and 62.40 N for conventional hemoclips, mucosal PSS, seromuscular PSS, mucosal OTSC, seromuscular OTSC, and surgical suture, respectively. Complete inverted closure was observed for seromuscular PSS, seromuscular OTSC, and surgical suture. The mean leak pressure was 13.7 and 24.8 mmHg in the PSS and OTSC group, respectively (P < 0.01). The mean procedure time was 541 and 169 s in the PSS and OTSC group, respectively (P < 0.01). Complete inverted closure was observed in OTSC alone.ConclusionThe OTSC, which allows complete inverted closure, showed greater closure strength than PSS. Considering the size limitation suitable for single OTSC, a therapeutic strategy for closing the larger size is further warranted.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据