4.4 Article

Donor site morbidity after computer assisted surgical reconstruction of the mandible using deep circumflex iliac artery grafts: a cross sectional study

期刊

BMC SURGERY
卷 23, 期 1, 页码 -

出版社

BMC
DOI: 10.1186/s12893-022-01899-z

关键词

Mandible reconstruction; Deep circumflex iliac artery; Comorbidity

类别

向作者/读者索取更多资源

This study investigated comorbidity of the hip following deep circumflex iliac artery (DCIA) graft raising using CAD/CAM techniques. The results showed a significant correlation between graft volume and skin incision length with postoperative donor site morbidity. The study suggests that a minimally invasive approach could help reduce postoperative symptomatology in CAD/CAM surgery.
Background Computer Assisted Design and Computer Assisted Manufacturing (CAD/CAM) have revolutionized oncologic surgery of the head and neck. A multitude of benefits of this technique has been described, but there are only few reports of donor site comorbidity following CAD/CAM surgery.Methods This study investigated comorbidity of the hip following deep circumflex iliac artery (DCIA) graft raising using CAD/CAM techniques. A cross-sectional examination was performed to determine range of motion, muscle strength and nerve disturbances. Furthermore, correlations between graft volume and skin incision length with postoperative donor site morbidity were assessed using Spearman's rank correlation, linear regression and analysis of variance (ANOVA).Results Fifteen patients with a mean graft volume of 21.2 +/- 5.7 cm(3) and a mean incision length of 228.0 +/- 30.0 mm were included. Patients reported of noticeable physical limitations in daily life activities (12.3 +/- 11.9 weeks) and athletic activities (38.4 +/- 40.0 weeks in mean) following surgery. Graft volume significantly correlated with the duration of the use of walking aids (R = 0.57; p = 0.033) and impairment in daily life activities (R = 0.65; p = 0.012). The length of the scar of the donor-site showed a statistically significant association with postoperative iliohypogastric nerve deficits (F = 4.4, p = 0.037). Patients with anaesthaesia of a peripheral cutaneous nerve had a larger mean scar length (280 +/- 30.0 mm) than subjects with hypaesthesia (245 +/- 10.1 mm) or no complaints (216 +/- 27.7 mm).Conclusions Despite sophisticated planning options in modern CAD/CAM surgery, comorbidity of the donor site following iliac graft harvesting is still a problem. This study is the first to investigate comorbidity after DCIA graft raising in a patient group treated exclusively with CAD/CAM techniques. The results indicate that a minimal invasive approach in terms of small graft volumes and small skin incisions could help to reduce postoperative symptomatology.Trial registration Retrospectively registered at the German Clinical Trials Register (DRKS-ID: DRKS00029066); registration date: 23/05/2022

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据