4.6 Article

Synthesis of a New Flocculant from Waste Polystyrene: Plastic Recycling Industry Wastewater Treatability

期刊

WATER AIR AND SOIL POLLUTION
卷 234, 期 2, 页码 -

出版社

SPRINGER INT PUBL AG
DOI: 10.1007/s11270-023-06104-2

关键词

Plastic washing wastewater; Waste polystyrene sulfonation; Coagulation-flocculation; Turbidity; COD; Oil grease

向作者/读者索取更多资源

This study investigates the treatment of HDPE, LDPE, PET, and PP plastic washing wastewater using sulfonated polystyrene as a flocculant. The results show that this flocculant effectively removes turbidity, COD, SS, and oil grease from the wastewater, providing a promising solution for the treatment of plastic washing wastewater.
HDPE (high-density polyethylene), LDPE (low-density polyethylene), PET (polyethylene terephthalate), and PP (polypropylene) plastic washing wastewater contains high concentrations of turbidity, COD (chemical oxygen demand), SS (suspended solids), and oil grease that lead to an increase in the pollution load of the wastewater treatment plant. Plastics washed in plastic recycling plants produce large volumes of wastewater. In this study, the use of sulfonated polystyrene as a flocculant for the treatment of these wastewaters, which is not found in the literature, was studied. A flocculant was synthesized from waste polystyrene (FSPS) by sulfonation, by cyclohexane, H2SO4, and P2O5 modification. This flocculant was used in the coagulation-flocculation treatment of plastic washing wastewater. Turbidity, COD, SS, and oil grease were determined for the supernatant. Effects of pH were studied at pH 3-13 intervals. Alum and FeCl3 were used as conventional coagulants at 15-1000 mg/L doses. The FSPS and polyelectrolyte (PEL) were used as flocculants at between 5 and 50 mg/L dosage. For HDPE washing wastewater (FeCl3 + FSPS), turbidity, COD, SS, and oil grease removal efficiencies are 96%, 92%, 86%, and 50%, respectively. For LDPE washing wastewater (FeCl3 + FSPS), turbidity, COD, SS, and oil grease removal efficiencies are 99%, 60%, 35%, and 75%, respectively. For PET washing wastewater (alum + FSPS), turbidity, COD, SS, and oil grease removal efficiencies are 94%, 70%, 99%, and 55%, respectively. For PP washing wastewater (alum + FSPS), turbidity, COD, SS, and oil grease removal efficiencies are 98%, 82%, 93%, and 89%, respectively. It was observed that treatment of synthesized FSPS flocculant resulted in higher or similar results of PEL.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据