4.6 Article

Measurement System for Short-Pulsed Magnetic Fields

期刊

SENSORS
卷 23, 期 3, 页码 -

出版社

MDPI
DOI: 10.3390/s23031435

关键词

colossal magnetoresistance; MOCVD technology; nanostructured manganite films; resistance relaxation processes; pulsed magnetic field; magnetic field sensors; magnetic field measurement system

向作者/读者索取更多资源

This article presents a measurement system based on the colossal magnetoresistance CMR-B-scalar sensor for short-duration high-amplitude magnetic fields. The system includes a magnetic field sensor made from nanostructured manganite film and a magnetic field recording module. The memory effect of manganite films doped with different amounts of Co and Mn was investigated, showing that LSMCO films are preferred for low-temperature applications and LSMO films with increased Mn content for higher temperatures. To avoid parasitic signals, a bipolar-pulsed voltage supply and a shielded measurement module were used. The developed system can measure high-pulsed magnetic fields with pulse durations in the order of microseconds.
A measurement system based on the colossal magnetoresistance CMR-B-scalar sensor was developed for the measurement of short-duration high-amplitude magnetic fields. The system consists of a magnetic field sensor made from thin nanostructured manganite film with minimized memory effect, and a magnetic field recording module. The memory effect of the La1-xSrx(Mn1-yCoy)(z)O-3 manganite films doped with different amounts of Co and Mn was investigated by measuring the magnetoresistance (MR) and resistance relaxation in pulsed magnetic fields up to 20 T in the temperature range of 80-365 K. It was found that for low-temperature applications, films doped with Co (LSMCO) are preferable due to the minimized magnetic memory effect at these temperatures, compared with LSMO films without Co. For applications at temperatures higher than room temperature, nanostructured manganite LSMO films with increased Mn content above the stoichiometric level have to be used. These films do not exhibit magnetic memory effects and have higher MR values. To avoid parasitic signal due to electromotive forces appearing in the transmission line of the sensor during measurement of short-pulsed magnetic fields, a bipolar-pulsed voltage supply for the sensor was used. For signal recording, a measurement module consisting of a pulsed voltage generator with a frequency up to 12.5 MHz, a 16-bit ADC with a sampling rate of 25 MHz, and a microprocessor was proposed. The circuit of the measurement module was shielded against low- and high-frequency electromagnetic noise, and the recorded signal was transmitted to a personal computer using a fiber optic link. The system was tested using magnetic field generators, generating magnetic fields with pulse durations ranging from 3 to 20 mu s. The developed magnetic field measurement system can be used for the measurement of high-pulsed magnetic fields with pulse durations in the order of microseconds in different fields of science and industry.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据