4.6 Article

Measurement of Restrained and Unrestrained Shrinkage of Reinforced Concrete Using Distributed Fibre Optic Sensors

期刊

SENSORS
卷 22, 期 23, 页码 -

出版社

MDPI
DOI: 10.3390/s22239397

关键词

distributed fibre optic strain sensing; shrinkage; reinforced concrete; restrained shrinkage; unrestrained shrinkage; functionally graded concrete; low carbon concrete

向作者/读者索取更多资源

Shrinkage is a complex time-dependent phenomenon in reinforced concrete structures, influenced by various factors. Distributed fibre optic sensing provides a method to measure both restrained and unrestrained shrinkage in small-scale specimens and structural elements. The study developed and evaluated methods to measure distributed unrestrained shrinkage strains and studied restrained shrinkage strains in different types of structural members. The findings showed high variability in unrestrained shrinkage strains depending on location and non-uniform shrinkage strain distributions in restrained shrinkage strains due to functional grading and high supplementary cementitious material concretes.
Shrinkage is an important component of the behaviour of reinforced concrete (RC) structures, however, the number of variables that affect shrinkage make it a complex time-dependent phenomenon. Additionally, as new concrete materials with lower embodied carbon gain popularity, there is a need for an in-depth understanding into their shrinkage behaviour before they can be widely adopted by industry. Currently, the shrinkage behaviour of concrete is studied using discrete measurements on small-scale unrestrained prisms. Distributed fibre optic sensing (DFOS) potentially provides a method of measuring both restrained (with reinforcement) and unrestrained (without reinforcement) shrinkage in both small-scale specimens and structural elements. In the current study, methods of measuring distributed unrestrained shrinkage strains were developed and evaluated, and the restrained shrinkage strains in different types of structural members were studied. Unrestrained shrinkage strains were measured using fibres optic cables embedded in small concrete prisms, while restrained shrinkage strains were measured with fibres bonded to the longitudinal reinforcement. Unrestrained shrinkage strains were found to be highly variable (as large as 3800 microstrain range) depending on location, but further research needs to be undertaken to account for end effects, early-stage shrinkage, and bond between the fibre optic cable and the concrete. Restrained shrinkage strains from structural members revealed non-uniform shrinkage strain distributions along member length due to functional grading as well as high supplementary cementitious material concretes, suggesting that shrinkage models will need to account for this variability.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据