4.7 Article

Clinical Application of Ultrahigh-Field-Strength Wrist MRI: A Multireader 3-T and 7-T Comparison Study

期刊

RADIOLOGY
卷 307, 期 2, 页码 -

出版社

RADIOLOGICAL SOC NORTH AMERICA (RSNA)
DOI: 10.1148/radiol.220753

关键词

-

向作者/读者索取更多资源

This study compared the subjective image quality of 3T and 7T ultrahigh-field-strength wrist MRI and found that 7T MRI had potential advantages in cartilage assessment, while 3T MRI was superior in evaluating the triangular fibrocartilage complex and wrist ligaments.
Background: Ultrahigh-field-strength MRI at 7 T may permit superior visualization of noninflammatory wrist pathologic conditions, particularly due to its high signal-to-noise ratio compared with the clinical standard of 3 T, but direct comparison studies are lacking. Purpose: To compare the subjective image quality of 3-T and 7-T ultrahigh-field-strength wrist MRI through semiquantitative scoring of multiple joint tissues in a multireader study.Materials and Methods: In this prospective study, healthy controls and participants with chronic wrist pain underwent 3-T and 7-T MRI (coronal T1-weighted turbo spin-echo [TSE], coronal fat-suppressed proton-density [PD]-weighted TSE, transversal T2 -weighted TSE) on the same day, from July 2018 to June 2019. Images were scored by seven musculoskeletal radiologists. The over-all image quality, presence of artifacts, homogeneity of fat suppression, and visualization of cartilage, the triangular fibrocartilage complex (TFCC), and scapholunate and lunotriquetral ligaments were semiquantitatively assessed. Pairwise differences between 3 T and 7 T were assessed using the Wilcoxon signed-rank test. Interreader reliability was determined using the Fleiss kappa.Results: In total, 25 healthy controls (mean age, 25 years +/- 4 [SD]; 13 women) and 25 participants with chronic wrist pain (mean age, 39 years +/- 16; 14 men) were included. Overall image quality (P = .002) and less presence of artifacts at PD-weighted fat-suppressed MRI were superior at 7 T. T1-and T2-weighted MRI were superior at 3 T (both P < .001), as was fat suppression (P < .001). Visualization of cartilage was superior at 7 T (P < .001), while visualization of the TFCC (P < .001) and scapholunate (P = .048) and lunotriquetral (P = .04) ligaments was superior at 3 T. Interreader reliability showed slight to substantial agreement for the detected pathologic conditions (kappa = 0.20-0.64).Conclusion: A 7-T MRI of the wrist had potential advantages over 3-T MRI, particularly in cartilage assessment. However, superior-ity was not shown for all parameters; for example, visualization of the triangular fibrocartilage complex and wrist ligaments was superior at 3 T. (c) RSNA, 2023

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据