4.6 Article

Enhancing φ-sensitivity of ignition delay times through dilution of fuel-air mixture

期刊

PROCEEDINGS OF THE COMBUSTION INSTITUTE
卷 39, 期 4, 页码 4939-4947

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.proci.2022.09.055

关键词

phi-sensitivity; Dilution; Ignition delay; Iso-octane; Advanced fuel ignition delay analyzer

向作者/读者索取更多资源

This study aims to quantify the effect of dilution on the phi-sensitivity of isooctane using a combined experiment-simulation approach. The results showed that the enhancement of phi-sensitivity with dilution strategy was maximized in the low-temperature chemistry regime, increasing phi-sensitivity by 77% with a 28.6% dilution rate. This study is the first experiment-simulation combined research to quantify the effect of dilution on phi-sensitivity, facilitating the kinetics model refinement for better reproduction.
The high phi-sensitivity (eta) of ignition delay time (tau IDT) is one of the desirable fuel properties for the high-load extension of advanced compression ignition engine. Recent studies revealed the effectiveness of a high dilution rate (x(D)) for enhancing eta at the engine-relevant conditions. This study aims to quantify the effect of dilution on the eta of isooctane using a combined experiment-simulation approach. The ignition delay of the isooctane/air mixture was measured with an Advanced Fuel Ignition Delay Analyzer (AFIDA) over the temperature range of 623 - 923 K at 10 bar pressure with global phi = 0.3 - 0.6, with and without 28.6% of additional N-2 dilution. For precise evaluation of experimental eta, the facility effect of the AFIDA experiment was characterized with three-dimensional computational fluid dynamics (3-D CFD) simulation. The temperature in the combustion chamber from 3-D CFD indicated a substantial temporal dependency, varying up to similar to 52 K by charge-cooling of fuel injection and heat transfer from the wall. We introduced the dimensionless number theta(t) for characterizing the temporal profile of chamber temperature. Consideration of the facility effect using theta(t) resulted in better agreement between the experimental eta and zero-dimensional (0-D) kinetics simulation. The refined. were then further utilized to quantify the effectiveness of dilution to eta. The extent of eta enhancement with dilution strategy was maximized at the low-temperature chemistry regime, increasing eta by 77% with a 28.6% dilution rate. Further analysis on the dilution effect was carried out using 0-D kinetics simulation, revealing the critical dimensionless numbers relevant to the effectiveness of dilution to eta enhancement. This study is the first experiment-simulation combined research to quantify the effect of dilution on eta, facilitating the kinetics model refinement for better reproduction of phi-sensitivity. (c) 2022 The Combustion Institute. Published by Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据