4.6 Article

Optimization of Coagulation-Flocculation Process in Efficient Arsenic Removal from Highly Contaminated Groundwater by Response Surface Methodology

期刊

MOLECULES
卷 27, 期 22, 页码 -

出版社

MDPI
DOI: 10.3390/molecules27227953

关键词

arsenic removal; coagulation-flocculation; ferric chloride; Box-Ehnken design; groundwater treatment

资金

  1. Kharazmi University, Iran National Science Foundation [98011284]
  2. Silk Road Foundation from the Chinese Academy of Sciences [GJHZ2080]

向作者/读者索取更多资源

This study explored the coagulation-flocculation process using ferric chloride coagulant and polyacrylamide k16 co-coagulant for As(V) removal. The effects of various operating variables on removal efficiency were investigated. The results showed that coagulant dosing, co-coagulant dosing, pH, and fast mixing speed had the most significant impact on As(V) removal efficiency.
Elevated arsenic (As) contamination in water, especially groundwater, has been recognized as a major problem of catastrophic proportions. This work explores As(V) removal via the coagulation-flocculation process by use of ferric chloride coagulant and polyacrylamide k16 co-coagulant as a first time. The effects of major operating variables such as coagulant dosing (50, 125 and 200 mg/L), co-coagulant dosing (5, 12.5 and 20 mg/L), pH (6, 7and 8), fast mixing time (1, 2 and 3 min), and fast mixing speed (110, 200 and 300 rpm) on As(V) removal efficiency were investigated by a Box-Behnken statistical experiment design (BBD) and response surface methodology (RSM). According to factors F values, coagulant dosing, rapid mixing speed, pH, and co-coagulant dosing showed the most effect on As(V) removal efficiency, and the rapid mixing time factor indicated the slightest effect. The proposed quadratic model was significant with a p value < 0.0001 and has satisfactorily described the experimental data with R-2 and adjusted R-2 values of 0.9855 and 0.9738, respectively. Predicted model optimal conditions with target of complete As(V) removal were coagulant dosing = 197.63 ppm, co-coagulant dosing = 19.55 ppm, pH = 7.37, fast mixing time = 1.43 min and fast mixing speed = 286.77 rpm. The treatment of Nazarabad well water sample with an initial As(V) concentration of 5 mg/L under the optimal conditions removed 100% As(V) with the volume of produced sludge of 10.7 mL/200 mL. Increasing coagulant dosing, co-coagulant dosing, fast mixing time and fast mixing speed operation parameters from low-level to high-level values indicated 78%, 20%, 10.52% and 9.47% increases in volume of the produced sludge, respectively. However, a reduction of 13.63% in volume of the produced sludge resulted via pH increases.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据