4.4 Article

Detection of inflow obstruction in left ventricular assist devices by accelerometer: An in vitro study

相关参考文献

注意:仅列出部分参考文献,下载原文获取全部文献信息。
Article Engineering, Biomedical

Improved Detection Of Thromboembolic Complications In Left Ventricular Assist Device By Novel Accelerometer-Based Analysis

Itai Schalit et al.

Summary: This study aims to improve the diagnosis of thromboembolic complications in HVAD by using vibration analysis. Changes in nonharmonic amplitude (NHA) and the third harmonic amplitude were analyzed to detect thromboembolic events, and combining these two methods improved the positive predictive value.

ASAIO JOURNAL (2022)

Article Cardiac & Cardiovascular Systems

Inflow cannula obstruction of the HeartWare left ventricular assist device: what do we really know?

Federico Pappalardo et al.

Summary: This case report highlights the importance of early recognition of HVAD inflow cannula obstruction leading to in-pump thrombosis and complete cannula occlusion. Effective strategies and tools for the diagnosis and management of this complication are currently lacking.

CARDIOVASCULAR PATHOLOGY (2021)

Review Cardiac & Cardiovascular Systems

Integration of novel monitoring devices with machine learning technology for scalable cardiovascular management

Chayakrit Krittanawong et al.

Summary: Ambulatory monitoring is becoming increasingly important in cardiovascular care, but is limited by the unpredictability of cardiovascular events. Introduction of novel physiological biosignals may increase the frequency of abnormality detection, allowing for expert-level automated diagnosis, but raises concerns regarding accuracy and actionability. Utilizing analytical methods like machine learning may improve the accuracy and actionability of diagnoses, ultimately facilitating near-real-time diagnosis and therapy. Regulatory and ethical issues are recognized, but further technical and ethical challenges remain.

NATURE REVIEWS CARDIOLOGY (2021)

Article Engineering, Biomedical

Understanding the influence of left ventricular assist device inflow cannula alignment and the risk of intraventricular thrombosis

Michael Neidlin et al.

Summary: The study reveals the potential impact of inflow cannulation angles on thrombosis risk, suggesting that ideal inflow cannula alignment is towards the mitral valve and parallel to the septum. However, the optimal approach may vary depending on other patient factors and may change during the course of LVAD support.

BIOMEDICAL ENGINEERING ONLINE (2021)

Article Cardiac & Cardiovascular Systems

Primary results of long-term outcomes in the MOMENTUM 3 pivotal trial and continued access protocol study phase: a study of 2200 HeartMate 3 left ventricular assist device implants

Mandeep R. Mehra et al.

Summary: The study enrolled 2200 HM3 implanted patients and compared outcomes including survival and major adverse events at 2 years between CAP and pivotal trial cohorts. Despite sicker patients in the CAP group, the 2-year primary endpoint and overall survival were similar among CAP and pivotal cohorts.

EUROPEAN JOURNAL OF HEART FAILURE (2021)

Article Cardiac & Cardiovascular Systems

Comparing short-term outcome after implantation of the HeartWare® HVAD® and the Abbott® HeartMate 3®

Rene Schramm et al.

ESC HEART FAILURE (2020)

Article Computer Science, Information Systems

Detecting Suspected Pump Thrombosis in Left Ventricular Assist Devices via Acoustic Analysis

Beren Semiz et al.

IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS (2020)

Article Multidisciplinary Sciences

The misuse of colour in science communication

Fabio Crameri et al.

NATURE COMMUNICATIONS (2020)

Article Medicine, General & Internal

A Fully Magnetically Levitated Left Ventricular Assist Device - Final Report

M. R. Mehra et al.

NEW ENGLAND JOURNAL OF MEDICINE (2019)

Letter Cardiac & Cardiovascular Systems

Ischemic stroke and subsequent thrombosis within a HeartMate 3 left ventricular assist system: A cautionary tale

Ivan Netuka et al.

JOURNAL OF HEART AND LUNG TRANSPLANTATION (2018)

Letter Cardiac & Cardiovascular Systems

A case of an obstructive inflow thrombus in a HeartMate 3 from the left ventricle into the pump

Jaime-Juergen Eulert-Grehn et al.

JOURNAL OF HEART AND LUNG TRANSPLANTATION (2018)

Article Engineering, Biomedical

Accelerometer Detects Pump Thrombosis and Thromboembolic Events in an In vitro HVAD Circuit

Itai Schalit et al.

ASAIO JOURNAL (2018)

Review Cardiac & Cardiovascular Systems

Left ventricular assist device therapy in advanced heart failure: patient selection and outcomes

Finn Gustafsson et al.

EUROPEAN JOURNAL OF HEART FAILURE (2017)

Article Engineering, Biomedical

Echocardiographic outflow pump ramp test in centrifugal-flow left ventricular assist device

Attilio Iacovoni et al.

INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS (2017)

Article Cardiac & Cardiovascular Systems

Evaluation of the HeartWare ventricular assist device Lavare cycle in a particle image velocimetry model and in clinical practice

Daniel Zimpfer et al.

EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY (2016)

Letter Cardiac & Cardiovascular Systems

Thrombus around the redesigned HeartWare HVAD inflow cannula: A pathologic case series

Kyle C. Strickland et al.

JOURNAL OF HEART AND LUNG TRANSPLANTATION (2016)

Article Cardiac & Cardiovascular Systems

Diagnosis and Treatment Algorithm for Blood Flow Obstructions in Patients With Left Ventricular Assist Device

Anna Mara Scandroglio et al.

JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY (2016)

Review Medicine, General & Internal

Left ventricular assist device: a bridge to transplant or destination therapy?

Swati Patel et al.

POSTGRADUATE MEDICAL JOURNAL (2016)

Letter Cardiac & Cardiovascular Systems

Cerebral protection system applied during washout of thrombus occluding inflow cannula of HeartWare HVAD left ventricular assist device

Evgenij V. Potapov et al.

JOURNAL OF HEART AND LUNG TRANSPLANTATION (2015)

Article Engineering, Biomedical

Acoustic Analysis of a Mechanical Circulatory Support

Laila Hubbert et al.

ARTIFICIAL ORGANS (2014)

Article Engineering, Biomedical

Acoustic Spectral Analysis for Determining Pump Thrombosis in Rotary Blood Pumps

Friedrich Kaufmann et al.

ASAIO JOURNAL (2014)

Article Cardiac & Cardiovascular Systems

An analysis of pump thrombus events in patients in the Heart Ware ADVANCE bridge to transplant and continued access protocol trial

Samer S. Najjar et al.

JOURNAL OF HEART AND LUNG TRANSPLANTATION (2014)

Article Cardiac & Cardiovascular Systems

Algorithm for the diagnosis and management of suspected pump thrombus

Daniel J. Goldstein et al.

JOURNAL OF HEART AND LUNG TRANSPLANTATION (2013)

Article Cardiac & Cardiovascular Systems

Receiver-operating characteristic analysis for evaluating diagnostic tests and predictive models

Kelly H. Zou et al.

CIRCULATION (2007)