期刊
JOURNAL OF THERMAL SCIENCE
卷 32, 期 2, 页码 881-896出版社
SPRINGER
DOI: 10.1007/s11630-023-1751-9
关键词
free-piston engine generator; disturbance sources; operation stability; anti-disturbance ability
In this experimental study, the effect of disturbances on a methane-fueled free-piston engine generator (FPEG) was investigated. Four disturbance sources were identified and applied, including step change of external load, mixture flow rate fluctuation, random misfire of a cylinder, and elastic collision. The results showed that the FPEG achieved steady-state operation with load, but experienced frequency and fluctuation changes when the external load was instantaneously disconnected or connected, indicating a greater disturbance impact on operation stability during load connection. However, the FPEG demonstrated good anti-disturbance ability and continued to operate even when facing disturbances such as changes in external load, mixture flow rate, random misfire, and minor collisions.
Rating: 8/1
In this paper, the effect of disturbances on the operation process of a methane-fueled free-piston engine generator (FPEG) was experimentally investigated. Four disturbance sources, namely step change of external load, mixture flow rate fluctuation, random misfire of a cylinder, and elastic collision, were identified and applied to the FPEG. The results showed that the FPEG successfully achieved a steady-state operation with load. The maximum instantaneous electric power of 127 W and the average effective electric power of 38.9 W were obtained. When an external load was instantaneously disconnected, the engine frequency increased from 26.7 Hz to 31.3 Hz. The fluctuation amplitudes of induced voltage, pressure and compression ratio were 18.9%, 24.7% and 52.2% respectively in the disturbance. By contrast, when the external load was instantaneously connected, the corresponding values were 42.2%, 31.3% and 64.3% respectively, indicating that the instantaneous external load connection had a greater disturbance impact on the FPEG operation stability. Despite encountering the step change of external load, the FPEG can still restore stable operation and show good anti-disturbance ability. Compared with increasing mixture flow rate, reducing the mixture flow rate has a greater disturbance impact on the engine operation stability. Although random misfire of a cylinder will cause remarkable fluctuations in piston displacement and cylinder pressure, the FPEG will not stop running, but continues to work as a single-piston engine. Minor collision event may adversely affect the stability of engine operation, but will not lead to the FPEG shutdown. However, serious collision event may lead to ignition failure and shutdown accident.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据