4.5 Article

Low vs Standard-Dose Indocyanine Green in the Identification of Biliary Anatomy Using Near-Infrared Fluorescence Imaging: A Multicenter Randomized Controlled Trial

期刊

JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS
卷 236, 期 4, 页码 711-717

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/XCS.0000000000000553

关键词

-

类别

向作者/读者索取更多资源

This study investigates the use of a lower dose of intravenous indocyanine green (ICG) to improve the visualization of biliary anatomy, and finds that low-dose ICG leads to quantitative improvement in biliary visualization by minimizing liver fluorescence.
BACKGROUND: Near-infrared fluorescence imaging using intravenous indocyanine green (ICG) facilitates intraoperative identification of biliary anatomy. We hypothesize that a much lower dose of ICG than the standard decreases hepatic and background fluorescence and improves bile duct visualization.STUDY DESIGN: In this multicenter randomized controlled trial, 55 adult patients undergoing laparoscopic cholecystectomy were randomized to low-dose (0.05 mg) or standard-dose (2.5 mg) ICG preoperatively on the day of surgery. A quantitative assessment was performed on recorded videos from the operation using ImageJ software to quantify the fluorescence intensity of the bile duct, liver, and surrounding/background fat. Operating surgeons blinded to ICG dose provided a qualitative assessment of various aspects of the visualization of the extrahepatic biliary tree comparing near-infrared fluorescence to standard visible light imaging using a scale of 1 to 5 (1, unsatisfactory; 5, excellent). Quantitative and qualitative scores were compared between the groups to determine any significant differences between the doses.RESULTS: The bile duct-to-liver and bile duct-to-background fat fluorescence intensity ratios were significantly higher for the low-dose group compared with the standard-dose group (3.6 vs 0.68, p < 0.0001; and 7.5 vs 3.3, p < 0.0001, respectively). Low-dose ICG had a slightly higher (ie better) mean score on the qualitative assessment compared to the standard dose, although the differences were not statistically significant.CONCLUSIONS: Low-dose ICG leads to quantitative improvement of biliary visualization using near-infrared fluorescence imaging by minimizing liver fluorescence; this further facilitates routine use during hepatobiliary operations. (J Am Coll Surg 2023;236:711-717. (c) 2023 by the American College of Surgeons. Published by Wolters Kluwer Health, Inc. All rights reserved.)

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据