4.5 Article

Accurate Identification of Mucinous Pancreatic Cystic Lesions Using Small-Volume Analytes

期刊

JOURNAL OF SURGICAL RESEARCH
卷 284, 期 -, 页码 322-331

出版社

ACADEMIC PRESS INC ELSEVIER SCIENCE
DOI: 10.1016/j.jss.2022.08.014

关键词

Carcinoembryonic antigen; Gastricsin; Glucose; Pancreatic cystic lesions

类别

向作者/读者索取更多资源

This study compared the performance of gastricsin, glucose, and CEA as biomarkers for the classification of mucinous pancreatic cystic lesions. The results showed that gastricsin and glucose performed similarly to CEA, but required much smaller sample volumes.
Introduction: The accurate identification of mucinous pancreatic cystic lesions (PCLs) is paramount for cancer risk stratification. Cyst fluid carcinoembryonic antigen (CEA), the only routinely used test, requires high volumes and has low sensitivity. We aimed to compare the performance of two investigational small-volume biomarkers, glucose and the protease gastricsin, to CEA for PCL classification.Methods: We obtained cyst fluid samples from 81 patients with pathologically confirmed PCLs from four institutions between 2003 and 2016. Gastricsin activity was measured using an internally quenched fluorescent substrate. Glucose levels were measured with a standard glucometer. CEA levels were obtained from the medical record. Models using Clas-sification and Regression Trees were created to predict mucinous status. Model performance was evaluated using nested cross-validation.Results: Gastricsin activity, CEA, and glucose levels from patients with mucinous (n = 50) and nonmucinous (n = 31) PCLs were analyzed. Area under the curve (AUC) was similar for individual classifiers (gastricsin volume normalized [GVN] 0.88; gastricsin protein concentration normalized [GPN] 0.95; glucose 0.83; CEA 0.84). The combination of two classifiers did not significantly improve AUC, with CEA + GVN (0.88) performing similarly to CEA + GPN (0.95), GVN + glucose (0.87), GPN + glucose (0.95), and CEA + glucose (0.84). The three-analyte combination performed similarly to single and dual classifiers (GPN + glucose + CEA AUC 0.95; GVN + glucose + CEA AUC 0.87). After multiple comparison corrections, there were no significant differences between the individual, dual, and triple classifiers.Conclusions: Gastricsin and glucose performed similarly to CEA and required <5% of the volume required for CEA; these classifiers may be useful in patients with limited cyst fluid. Future multicenter prospective studies are needed to validate and compare these novel small-volume biomarkers.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据