4.4 Article

Regression-Based Interpretation Method for Confined Aquifer Pumping Tests

期刊

JOURNAL OF HYDROLOGIC ENGINEERING
卷 28, 期 2, 页码 -

出版社

ASCE-AMER SOC CIVIL ENGINEERS
DOI: 10.1061/(ASCE)HE.1943-5584.0002235

关键词

Confined aquifer; Inverse problem; Pumping test; Regression; Parameter estimation

向作者/读者索取更多资源

This study proposes a regression-based solution approach for analyzing constant-discharge pumping tests in confined aquifers. By utilizing the similarity solution, a regression model was developed to establish a link between a selected drawdown value and its dimensionless counterpart. The proposed method eliminates the difficulties encountered with conventional methods and provides highly accurate parameter estimates.
The constant-discharge pumping test is a widely used aquifer characterization tool for estimating hydrogeological parameters. Various graphical and numerical solution techniques have been devised for interpretation of pumping test results. This study proposes an alternative regression-based solution approach for analyzing pumping tests conducted in nonleaky, confined aquifers. A regression model was developed by making use of the similarity solution that describes the temporal drawdown behavior at a monitoring well within a pumping period. The field curve obtained from a pumping test (drawdown versus time data) and the theoretical type curve (dimensionless drawdown versus dimensionless time) exhibit identical behavior in logarithmic scale. Correspondingly, based on the equivalence of the area above these two curves, the proposed regression equation establishes a link between a selected drawdown value and its dimensionless counterpart. Once this drawdown value is associated with the corresponding dimensionless drawdown, the explored aquifer transmissivity and storativity can be retrieved easily with the similarity solution. The proposed fit equation enables users to retrieve hydrogeological parameters effortlessly by eradicating the difficulties encountered while implementing conventional graphical or optimization-based methods. The method was tested for a large number of hypothetical noise-free and noise-perturbed time drawdown data sets, each synthesized with different aquifer parameters within a wide range, and in all these attempts the proposed algorithm achieved providing highly accurate parameter estimates. In addition, two published test cases were employed to assess the estimation performance of the method in comparison with the existing techniques. The developed solution scheme was revealed to yield results in very good agreement with those reported in previous works. Considering the accuracy of the method and the ease of its implementation, the proposed approach can be a practical tool for analyzing constant-discharge tests performed in confined aquifers.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据