期刊
INTERNATIONAL JOURNAL OF EXERGY
卷 40, 期 2, 页码 182-197出版社
INDERSCIENCE ENTERPRISES LTD
DOI: 10.1504/IJEX.2023.128784
关键词
exergy analysis; exergy efficiency; exergy destruction; steam power plant; design load; operating loads; full load; partial load; off-design
Exergy performances of a 220 MW gas-fired steam turbine power plant were investigated at full and partial loads using full and partial plant load design data. The boiler exergy efficiencies were the least at 100%, 75% and 50% loads, with values of 42.8%, 42.5% and 41.8% respectively. The condenser exergy efficiency was lowest at 25% load (40.29%). High pressure heater 6 had the highest exergy efficiencies across all loads. The overall exergy efficiencies of the entire plant increased from 28.29% at 25% load to 33.18% at 100% load.
Exergy performances were investigated for a 220 MW gas-fired steam turbine power plant operating at full and partial loads. The analyses relied on full and partial plant load design data. Compared to other components, boiler exergy efficiencies, 42.8%, 42.5% and 41.8%, were the least at 100%, 75% and 50% loads, respectively. The condenser exergy efficiency was least (40.29%) at 25% load. Exergy efficiencies of high pressure heater 6 were the highest across all the loads. For the entire plant, overall exergy efficiencies increased from 28.29% at 25% load to 33.18% at 100% load.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐