4.6 Article

Experimental and numerical study on corona onset threshold under combined AC-DC voltages in Wire-Plane electrodes

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.ijepes.2022.108479

关键词

Corona discharge; Corona onset voltage; Combined AC-DC voltages; Wire-plane electrode; Space charge

资金

  1. National Natural Science Foundation of China [51877082]
  2. State Key Laboratory of Reliability and Intelligence of Electrical Equipment [EERIKF2019002]
  3. Fundamental Research Funds for the Central Universities [2019MS011]

向作者/读者索取更多资源

This paper studied the phenomenon of corona discharge under combined AC-DC voltages, establishing an experimental platform and a new corona model to measure the variation of corona onset voltage. The results showed that conductor radius and spacing affected the corona onset curve, while residual space charges had a blocking effect on corona discharge, leading to higher corona onset voltages.
With the large-scale application of hybrid HVDC/HVAC transmission technology, the phenomenon of corona discharge is also intensified. This paper attempts to provide a comprehensive understanding of the variation of corona onset voltage under combined AC-DC voltages. In this paper, an experimental platform for measuring corona onset voltage and current pulses of wire-plane electrode under combined AC-DC voltages was built. A new corona model of wire-plane electrode under combined AC-DC voltages was also established by using the fluid model and the ion flow field model. The corona onset voltages of wire-plane electrode under different ratios of AC and DC voltages, conductor radius and conductor spacing were measured. It turned out that the conductor radius affected the intercept of the corona onset curve, while the conductor spacing affected the slope. In addition, the type of corona only affected the intercept of the corona onset curve, not the slope. With the same fixed voltage of non-corona conductor, the corona onset voltage of the DC-side positive corona was the largest, followed by the DC-side negative corona, then was the AC-side positive half-cycle corona, and the smallest was the AC-side negative half-cycle corona. The interaction between AC voltage and DC voltage was approximately linear. The calculations of the model illustrated that the residual space charges had a blocking effect on corona discharge. Therefore, the more residual space charge was, the higher corona onset voltage would be.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论