4.6 Article

Indoor PM2.5 from occupied residences in Sweden caused higher inflammation in mice compared to outdoor PM2.5

期刊

INDOOR AIR
卷 32, 期 12, 页码 -

出版社

WILEY-HINDAWI
DOI: 10.1111/ina.13177

关键词

aerosol; home; indoor/outdoor ratio; physicochemical characteristics; PM2.5; real-life exposure; toxicity

资金

  1. Svenska Forskningsradet Formas
  2. Swedish Energy Agency
  3. FFIKA, Focused Research Effort on Chemicals in the Working Environment from the Danish Government
  4. [942-2015-1029]
  5. [2016-0079]
  6. [43092-1]

向作者/读者索取更多资源

This study aimed to compare the relative toxicity and physicochemical properties of indoor and outdoor PM2.5. The results showed that indoor PM2.5 had higher relative concentrations of metals, PAHs, and endotoxins compared to outdoor PM2.5, leading to significantly higher lung inflammation and acute-phase response. However, neither indoor nor outdoor PM2.5 caused genotoxicity.
We spend most of our time indoors; however, little is known about the effects of exposure to aerosol particles indoors. We aimed to determine differences in relative toxicity and physicochemical properties of PM2.5 collected simultaneously indoors (PM2.5 INDOOR) and outdoors (PM2.5 OUTDOOR) in 15 occupied homes in southern Sweden. Collected particles were extracted from filters, pooled (indoor and outdoor separately), and characterized for chemical composition and endotoxins before being tested for toxicity in mice via intratracheal instillation. Various endpoints including lung inflammation, genotoxicity, and acute-phase response in lung and liver were assessed 1, 3, and 28 days post-exposure. Chemical composition of particles used in toxicological assessment was compared to particles analyzed without extraction. Time-resolved particle mass and number concentrations were monitored. PM(2.5 INDOOR )showed higher relative concentrations (mu g mg(-1)) of metals, PAHs, and endotoxins compared to PM2.5 OUTDOOR. These differences may be linked to PM2.5 INDOOR. causing significantly higher lung inflammation and lung acute-phase response 1 day post-exposure compared to PM2.5 OUTDOOR and vehicle controls, respectively. None of the tested materials caused genotoxicity. PM2.5 INDOOR displayed higher relative toxicity than PM2.5 OUTDOOR under the studied conditions, that is, wintertime with reduced air exchange rates, high influence of indoor sources, and relatively low outdoor concentrations of PM. Reducing PM2.5 INDOOR exposure requires reduction of both infiltration from outdoors and indoor-generated particles.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据